Specifications
Distribution Products Catalog CA08101001E—October 2010 www.eaton.com 33
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16.3
Tr a n s f er Switches
Breaker-Based Designs
Automatic Wallmount
Contents
Description Page
Molded Case Switches—Manual Wallmount. . . . . . . . . . . . 26
Molded Case Switches—Non-Automatic Wallmount. . . . . . 30
Molded Case Switches—Automatic Wallmount
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . 36
Catalog Number Selection. . . . . . . . . . . . . . . . . . . . . . . . 36
Technical Data and Specifications . . . . . . . . . . . . . . . . . . 37
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Maintenance Bypass Switches—Type MBHE 100–1000A . 39
Molded Case Switches—Automatic Wallmount
Product Description
Eaton’s wallmount transfer
switches are designed for a
variety of standby power
applications for critical loads.
They provide flexibility,
reliability and value in a
compact package. In the
event of a primary power
source interruption, a transfer
switch provides an effective
means to transfer the load
circuits to an alternate power
source while reducing the
possibility of injury or
property damage.
Wallmount transfer switches
meet or exceed all industry
standards for endurance,
reliability and performance.
These breaker-based designs
can be applied with the
ATC-100, ATC-300 or
ATC-600 controllers.
Application Description
Suitable for emergency and
standby systems (all loads).
Industrial Design Highlights
●
Double-throw,
mechanically interlocked
transfer mechanism
●
High withstand and
closing ratings
●
Seismic Zone 4 qualified
(BOCA
®
, CBC, IBC, UBC)
Standard Features
●
Auxiliary relay contacts:
●
Source 1 present
2NO and 2NC
●
Source 2 present
2NO and 2NC
●
Switch position indication
contacts:
●
Source 1 position
1NO and 1NC
●
Source 2 position
1NO and 1NC
●
Source 1 and Source 2
sensing:
●
Undervoltage/
underfrequency
●
Overvoltage/
overfrequency
●
Three-phase rotation
protection
●
Three-phase voltage
unbalance/loss
●
Pretransfer signal
contacts 1NO/1NC
●
Go to emergency
(Source 2)
●
Seven field-programmable
time delays
●
LCD-based display for
programming, system
diagnostic and Help
message display
●
Mimic diagram with source
available and connected
LED indication
●
Time-stamped history log
●
System TEST pushbutton
●
Programmable plant
exerciser—OFF, daily,
7-, 14-, 28-day interval
selectable run time
0–600 minutes no load/
load with fail-safe
●
Safe manual operation
under full load with
permanently affixed
operating handle
Optional Features
●
Suitable for use as service
equipment in the standard
enclosure size
●
Available TVSS for power/
controller, engine start
circuit, phone and cable
connections
●
Integrated distribution
panels
●
Field-selectable multi-tap
transformer
panel permits
operation on a wide range
of system voltages
●
Integral overcurrent
protection
●
Not available on contactor
transfer switch
●
Space heater with
thermostat
●
Ammeter—load side
●
Stainless steel cover
for controller
F
eatures,
B
ene
fi
ts an
d
F
unct
i
ons