Specifications
30 Distribution Products Catalog CA08101001E—October 2010 www.eaton.com
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16.3
Tr a n s f er Switches
Breaker-Based Designs
Non-Automatic Wallmount
Contents
Description Page
Molded Case Switches—Manual Wallmount . . . . . . . . . . . 26
Molded Case Switches—Non-Automatic Wallmount
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . 31
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 31
Technical Data and Specifications . . . . . . . . . . . . . . . . . . 31
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Molded Case Switches—Automatic Wallmount . . . . . . . . . 33
Maintenance Bypass Switches—Type MBHE 100–1000A . 39
Molded Case Switches—Non-Automatic Wallmount
Product Description
Eaton’s wallmount non-
automatic transfer switches
are designed for a variety of
standby power applications
for critical loads.
In the event of a primary
power source interruption,
the user can manually
transfer the load circuits to
the standby power source
through the use of an
external pushbutton. Once
primary power has been
restored, the user can
manually transfer the load
circuits back to the primary
power source through the
use of an external
pushbutton.
Non-Automatic Switch with Doors Closed
Note: Optional service entrance rating shown for this photo.
Device Panel Control
Switch, Service
Entrance Keyed
Switch and
Indication Lights
Service
Entrance
Label (Optional)
Application Description
Non-automatic transfer
switches cover applications
ranging from 30–1000A
through 600 Vac for manual
configurations, open
transition, standard or
service entrance.
Non-automatic transfer
switches are manually
initiated, but electrically
operated designs. Front
door-mounted controls allow
the operator to initiate the
transfer. Overcurrent trips
may be added to the design
for either or both the normal
and emergency source.
Service entrance ratings
are available.
Features and Benefits
Features
●
Molded case switch power
contact assemblies
●
Positive mechanical and
electrical interlocking
●
Permanently affixed
manual operating handle
●
Pushbutton operation
Benefits
●
High withstand, totally
enclosed for maximum arc
suppression and isolation
during power transfer
●
Optional trip units offer
system overcurrent
protection
●
Prevents the paralleling of
two sources of power
●
Permits safe and
convenient manual transfer
of power under load via
external pushbutton
initiated operation
Non-Automatic Transfer Switch
Device panel shows controls
to initiate the manual transfer
and control indicating lights.
In addition, an optional
service entrance rating may
be specified. Keyed switch is
mounted on the device panel.