Specifications

Distribution Products Catalog
CA08101001E—October 2010 www.eaton.com
3
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16.1
Tr a n s f er Switches
Tr a n s f er Switch Equipment
Transfer Switch Product Guide, continued
Key:
DO = Drawout
FM = Fixed mounted
MPB = Magnum power breaker
MPS = Magnum power switch
MCB = Molded case breaker
MCS = Molded case switch
Catalog
Numbering
System
Non-Automatic Molded Case Switch
(600 Vac) (30–4000A)
Automatic (Wallmount) Molded Case Switch
(600 Vac) (30–1000A)
Maintenance Bypass
(480 Vac) (100–1000A)
Type NT = Non-automatic
Refer to
Page
30
AT = Automatic
Refer to
Page
33
MB = Maintenance bypass
Refer to
Page
39
Orientation H = Horizontal
V= Vertical
H = Horizontal
V= Vertical
H = Horizontal
Logic E = Electromechanical 1 = ATC-100
3= ATC-300
I= ATC-600
E = Electromechanical
Frame Molded case device
FD = 30–150A
KD = 150–300A
LD = 400–600A
MD = 600–800A
NB = 800–1000A
Molded case device
FD = 30–200A
KD = 150–300A
LD = 400–600A
MD = 600–800A
NB = 800–1000A
(FD = 200A available on ATH3 only)
Molded case device
FD = 100–150A
KD = 150–300A
LD = 400–600A
MD = 600–800A
NB = 800 –1000A
Switch Fixed mount
A = FM, N (MCS), E (MCS)
B = FM, N (MCB), E (MCB)
C = FM, N (MCB), E (MCS)
D = FM, N (MCS), E (MCB)
Fixed mount
A = FM, N (MCS), E (MCS)
B = FM, N (MCB), E (MCB)
C = FM, N (MCB), E (MCS)
D = FM, N (MCS), E (MCB)
Fixed mount
A = FM, N (MCS), E (MCS)
Poles 2 = Two-pole
3 = Three-pole
4 = Four-pole (four-pole—3000A maximum)
2 = Two-pole
3 = Three-pole
4 = Four-pole
2 = Two-pole
3 = Three-pole
4 = Four-pole
Amperes 0030 = 30A
0070 = 70A
0100 = 100A
0150 = 150A
0225 = 225A
0300 = 300A
0400 = 400A
0600 = 600A
0800 = 800A
1000 = 1000A
0030 = 30A
0070 = 70A
0100 = 100A
0150 = 150A
0200 = 200A
0225 = 225A
0300 = 300A
0400 = 400A
0600 = 600A
0800 = 800A
1000 = 1000A
0100 = 100A
0150 = 150A
0225 = 225A
0300 = 300A
0400 = 400A
0600 = 600A
0800 = 800A
1000 = 1000A
Voltage A = 120V, 60 Hz
B= 208V, 60 Hz
E= 600V, 60 Hz
G= 220V, 50/60 Hz
H= 380V, 50 Hz
K= 600V, 50 Hz
O= 415V, 50 Hz
W= 240V, 60 Hz
X= 480V, 60 Hz
A= 120V, 60 Hz
B= 208V, 60 Hz
E= 600V, 60 Hz
G= 220V, 50/60 Hz
H= 380V, 50 Hz
K= 600V, 50 Hz
O= 415V, 50 Hz
W= 240V, 60 Hz
X= 480V, 60 Hz
A= 120V, 60 Hz
B= 208V, 60 Hz
W= 240V, 60 Hz
X= 480V, 60 Hz
Enclosure K = Open
S = NEMA 1
R = NEMA 3R
J = NEMA 12
L= NEMA 4
D = NEMA 4X (J, L and D 65 kAIC,
1200A
and below only)
K = Open
S = NEMA 1
J = NEMA 12
R = NEMA 3R
L= NEMA 4
D = NEMA 4X
K = Open
S = NEMA 1
J = NEMA 12
R = NEMA 3R
L= NEMA 4
D = NEMA 4X
Listing U = UL listed
R = UL recognized
X = No listing
U = UL listed
R = UL recognized
X = No listing
U = UL listed
R = UL recognized
X = No listing