Datasheet

Enclosure covers
Housing Insulated material
Connection type Screw terminal
Rod length mm 160
Notes The operating head can be rotated at 90° intervals to adapt to the specified approach direction.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
Technical data
General
Standards IEC/EN 60947
Climatic proofing Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30
Ambient temperature °C -25 - +70
Mounting position As required
Degree of Protection IP65
Terminal capacities
mm
2
Solid
mm
2
1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Flexible with ferrule
mm
2
1 x (0.5 - 1.5)
2 x (0.5 - 1.5)
Contacts/switching capacity
Rated impulse withstand voltage U
imp
V AC 6000
Rated insulation voltage U
i
V 500
Overvoltage category/pollution degree III/3
Rated operational current I
e
A
AC-15
24 V I
e
A 10
220 V 230 V 240 V I
e
A 6
380 V 400 V 415 V I
e
A 4
DC-13
24 V I
e
A 10
110 V I
e
A 1
220 V I
e
A 0.5
Supply frequency Hz max. 400
Short-circuit rating to IEC/EN 60947-5-1
max. fuse A gG/gL 6
Repetition accuracy mm 0.02
Rated conditional short-circuit current kA 1
Mechanical variables
Lifespan, mechanical Operations
x 10
6
8
Contact temperature of roller head °C ≦ 100
Mechanical shock resistance (half-sinusoidal shock, 20 ms)
Standard-action contact g 5
Snap-action contact g 2
Operating frequency Operations/h ≦ 6000
Actuation
Mechanical
Actuating force at beginning/end of stroke N 8.0/20.0
Actuating torque of rotary drives Nm 0.3
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation I
n
A 6
02/07/2019 Eaton 066943 ED2019 V52.0 EN 2 / 4