Specifications
67
www.eaton.com/powerquality 1300 UPS UPS
3kVA to 22kVA Power Conditioners
The extension of Sola ferroresonant power conditioners continues
through to 22kVA. These units are mostly suited to hardwired, fixed
installation applications for providing smooth stepless control of the
output voltage, attenuation of harmful impulses or surges and other
power line disturbances. Sola 200 power conditioners are ideally
suited to provide protection in computer rooms, regulation for scientific
instrumentation, plus protection and regulated power to sophisticated
computer based factory process equipment. To simplify installation, all
units are free standing and fitted with castors (excluding 22kVA) and
jacking feet. Connections are provided at the rear via a base plate cable
entry to an isolation switch.
The flexibility of Sola 200 power conditioners is increased on units
between 7.5kVA and 18kVA. These units can be field configured for
single phase or three phase operation. Sola 200 power conditioners (3 to
22kVA) incorporate approved surge withstand capabilities, as required
by ANSI/IEEE C62.41-1980.
Built to protect: Remote computer peripherals, copiers and laser
printers, process control equipment, CNC machinery, programmable
logical controls (PLC), photographic equipment and entire installations.
Specifications
Input
Voltage: 220, 230 or 240 Volt AC (Refer “Ordering
Details” for configuration options)
Frequency: 50 Hz
Input Voltage Range: + 10%, -20% (±40%)
Protection: ANSI/IEEE C62.41-1980 A and B
waveforms suppressed to safe levels.
Output
Nominal Voltage: 220 or 240 Volt AC
Frequency: 50 Hz
Voltage Regulation: ±3% for +10%, -20% input. +5%, -8% for
±40% input.
Control: AC on/off switch
Power Efficiency: 90%
Response/Correction
Time:
Return to regulation envelope within 30
msec.
Dynamic Response: Continuous and smooth correction for
input voltage fluctuations.
Overloads
200% of rated load for 10 seconds without
damage. 500% of rated load for 10 msec.
Electrical Noise Attenuation
Transverse Mode: 60 dB typical, (80 dB max.) 4kHz to 20 MHz
Common Mode: 120 dB typical, (140 dB max.) 2kHz to 1
MHz
Output Harmonic Less than 3% THD on linear loads.
Distortion
No greater than 5% on typical computer
loads.
Environmental
Operating Ambient: -20ºC to +50ºC
Relative Humidity: 0 to 95% non-condensing
Ventilation: Natural Convection Cooled
Status Indication
Power On: Amber lamp
Overload Protection
Output short circuit protection
Warranty
5 years
Ordering details
Rated
Output
kVA
Part Number
Configuration
Weight
(kg)
Enclosure
Size (Note 5)
3 200-26-730 1 Phase only 100 1
3 200-26-730-00** 1 Phase only 100 1
5 200-26-750 1 Phase only 155 2
5 200-26-750-HO*** 1 Phase only 155 2
7.5 200-26-775**** 1 or 3 Phase 215 2
9 200-26-790**** 1 or 3 Phase 270 2
12 200-26-812M**** 1 or 3 Phase 360 3
15 200-26-815**** 1 or 3 Phase 420 3
18 200-26-818**** 1 or 3 Phase 520 3
22.5 200-46-822**** 3 Phase only 595 4
Notes:
1. * For units with nominal Ph-N voltage of 220V specify 44 (as in 200-44-730)
for 3-18kVA units and 24 (as in 200-24-822) for 22.5kVA model. For units
with nominal Ph-N voltage of 230V specify 25 for 3-18kVA units and 35 for
22.5kVA.
2. ** Units fitted with WIP 15 plug and 4 x 10/15 Amp screw sockets
3. *** Units fitted with input terminal block and 4 x 10/15 amp screw sockets
4. To avoid nuisance tripping of input circuit breakers, we recommend the use
of "D" curve or motor start type circuit breakers. Current rating should be at
least one size larger than input current stated on unit
data plate. See manual or consult your sales representative for
further details.
5. Enclosure Sizes (mm): Size 1: 600 (H) x 400 (W) x 440 (D)
Size 2: 995 (H) x 525 (W) x 550 (D)
Size 3: 990 (H) x 800 (W) x 550 (D)
Size 4: 1236 (H) x 800 (W) x 550 (D)
6. **** 3 Phase loads to be star connected only. Power Conditioners NOT to be
used for Delta loads.
Sola 200