Specifications
65
www.eaton.com/powerquality 1300 UPS UPS
10. Portable Surge Filter, 1 Phase 10A &
16A, 25kA Primary and 140kA Primary
11. Single Phase Rack
Mounted Filter /PDU
Power Conditioners
Sola Power Conditioners
Eaton's Sola ferroresonant products are proven technology. In 1938,
Sola was awarded the first patent for ferroresonant power conditioners:
the constant voltage transformer. Since then, our technology has
remained at the forefront of ferroresonant power conditioning.
Today, Eaton's Sola ferroresonant power conditioners supply sinewave
output, which is especially important for computer applications.
Whether you purchase a model 200, 210 or 26 voltage regulator, you can
count on an average of 25 years service from your unit.
Every ferroresonant power conditioner is manufactured to exacting
specifications and is subject to rigorous quality control.
The ferroresonant power conditioners protect equipment from all power
problems, other than the complete loss of power. They excel at tightly
regulating the voltage, providing superior noise attenuation and are
ruggedly designed to withstand the harshest electrical environments.
Possessing no moving parts, ferroresonant power conditioners are
virtually maintenance free.
What is Ferroresonance?
Simply put, ferroresonance is the property of a transformer design in
which the transformer contains two (2) separate magnetic paths with
limited coupling between them. The output contains a parallel resonant
tank circuit and draws power from the primary to replace the power
delivered to the load.
Note that "resonance" in ferroresonance is similar to that in linear
circuits with series or parallel inductors and capacitors, where the
impedance peaks at a particular frequency. In a non linear circuit,
such as a ferroresonant transformer, "resonance" is used to reduce
the changes in supply voltage and provide more constant voltage to
the load.
A magnetic device is non linear. Its reluctance changes abruptly above
a certain magnetic flux density. At this point, the magnetic device is
defined as being in saturation.
The design of the ferroresonant transformer allows one magnetic path
to be in saturation, while the other is not. As a result, further change in
the primary voltage will not translate into changes in the saturated, or
secondary voltage, and voltage regulation results.
Typical Model 200 or 210 Performance
Features and Benefits
• Superior Low Line Performance
Specified performance is maintained for all loads 0 - 100% of nominal
rating
• Switchmode Computer Load Compatibility
Able to support typical computer loads when input supply mains
voltage is 50% below nominal
• 240 Volt, 230 Volt or 220 Volt Models
Separate models to suit different nominal supplies or particular nominal
output voltage requirements
• 200% Overload Rated
Suitable for use with computer start up overloads. Units are output
short circuit proof
• On Site Configuration
7.5 to 18kVA units can be site configured as Single Phase or Three
Phase operation, if required
• Selectable Voltages
Hardwired 26 Series units have selectable input and output voltages
• 5 Year Warranty
Exceptional MTBF (Mean Time Between Failure), an optimum
combination of performance to cost effective power conditioning