Specifications
EATON CORPORATION UPS and Power Quality Products Catalogue
56
Airf low management and racks
Rack containment
Eaton Heat Containment System (HCS)
Eaton's HCS is a simple, scalable and low cost solution to cool up to 25
kW or more per enclosure without the expense of adding supplemental
CRAC units to your data centre. This patented technology is available on
Eaton’s Paramount and Vantage S2 enclosure systems and can also be
field retrofitted to most manufacturers' enclosures. The HCS contains
and directs the heat exhaust of your IT equipment through the chimney
that is attached to the top rear of the enclosure. The hot air is then
ducted to your existing CRAC units through a plenum ceiling or high
air returns.
Active Airflow Manager
Eaton’s HCS pressure based system with active airflow, when combined
with best practices, improves performance metrics considerably.
Allocating the correct amount of airflow at known intake locations is
the key to reducing energy consumption while increasing equipment
performance. Best practices such as blanking panels, proper perforated
tile placement and the reduction of bypass airflow must be employed to
ensure desired results.
Features and benefits:
• SNMP managed device with user-friendly Web interface
• Controller continuously monitors pressure differentials to ensure that
air entering the enclosure and server is properly removed
• Local LEDs indicate fan status including fan fail and over temperature
• Manage up to 64 peer active Airflow Managers via Ethernet
• Two integrated temperature sensors with e-mail alert capabilities
• Redundant power input, C13 plug type is required for each input, 90-240
Vac supplied by enclosure PDU(s)
• Controller is RoHS compliant
• Utilisation as your capacity demands grow
• Dramatically increasing the reliability of the data centre increasing
their efficiency by operating at a higher Delta T (DT) centre, freeing up
stranded assets and lowering operational costs locations and it is also
field-installable on third-party enclosures
HCS for third-party racks
Converting existing enclosures to the HCS allows you to eliminate the
incremental capital expense associated with having to add more CRAC
units or other supplemental cooling.
Features and benefits:
• Implement heat containment operations by building up from existing
enclosures without having to re-route or disconnect cables and power
• By isolating the hot exhaust air from the cold supply air, you can load
over 25 kW of equipment in an enclosure
• Requires no additional air conditioners or other space consuming
supplemental equipment at the perimeter of the data centre, in-row
or overhead
• Eliminates chaos airflow results in a more predictable operating
environment, allowing you to drive efficient energy use and create a
reliable infrastructure for moves, additions and changes
The HCS allows for your
existing cable management
without the interruption of
re-routing or disconnecting
cables and power. Shown
here on Eaton's Paramount
Enclosure System.
Eaton’s P Series enclosure
with integrated HCS.
Optional fans (2)
Chimney
Tool-less fan access door
Chimney base