Specifications

2
EATON Power Xpert 9395 UPS Eaton.com/9395
Introduction and overview
For more than 40 years, Eaton
®
has been dedicated to delivering
the most technologically advanced products for our customers'
mission-critical applications a commitment exemplified by the
Power Xpert
TM
9395 UPS. With an unprecedented level of power
performance, reliability and energy savings, the state-of-the-art
9395 has raised the bar in three-phase power protection
technology.
The 9395 delivers a wide scope of superior customer-driven
benefits unmatched by competitive UPS solutions, including:
Leading sustainability
s(IGHESTEFlCIENCYRATINGSLOWERUTILITYCOSTS
s,OWESTTOTALCOSTOFOWNERSHIPANDLIFECYCLECARBONFOOTPRINT
s3MALLESTFOOTPRINTANDWEIGHT
s,OWESTTRANSPORTATIONANDINSTALLATIONCOSTS
Stronger power performance
s,OWESTINPUTTO4($ENHANCECOMPATIBILITYWITHUPSTREAM
power systems
s,OWESTOUTPUT4($
s/PTIMUMGENERATORSIZING
s0&#POWERSUPPLYCOMPATIBLE
Highest reliability and availability
s0OWERWARE(OT3YNC
®
wireless paralleling
s3UPERIORBATTERYMANAGEMENT
s)NHERENTREDUNDANCY
s3CALABLEARCHITECTURETHATADAPTSTOINCREASINGPOWER
requirements
Robust manageability
s3UPERIORCONTROLANDCONNECTIVITY
sINCHCOLORTOUCHSCREENDISPLAYPROVIDESMETERINGAND
management options
The reliable solution
Providing high availability for your critical systems at all times, the
9395 was designed with numerous technological advancements
THATCREATEANUNPRECEDENTEDLEVELOFRELIABILITYWHILEEMPHASIZING
serviceabilitylowering MTTR and enhancing availability.
Double-conversion design offers the highest
protection possible
Unlike some other commercially available UPS technologies, the
double-conversion design completely isolates output power from
ALLINPUTPOWERANOMALIESANDDELIVERSPERCENTCONDITIONED
perfect sine-wave output—regulating both voltage and frequency.
Even when presented with the most severe power disturbances,
POWEROUTPUTREMAINSSTABLE/UTPUTVOLTAGE4($ISHELDWITHIN
two percent of nominal specification for linear loads, and within
five percent for nonlinear loadsmaking the 9395 ideal for
supporting equipment that’s sensitive to a distorted voltage input.
Additionally, the 9395 excels at supporting leading power factor
loads, which are becoming more prevalent in new or updated
data centers. The 9395 handles leading loads, down to 0.9 power
factor, without de-rating.
Inherent redundancy option
Surveys focused on efficiency in data centers reveal that UPSs are
OFTENUNDERLOADEDnFREQUENTLYATLESSTHANPERCENT4OCAPITALIZE
on this trend and create even greater reliability, you have the option
to configure the 9395 with inherent redundancy. Traditional UPS
manufacturers can't deliver this additional availability without
adding a more costly second UPS module.
Inherent redundancy: When at or below 50 percent
capacity, the 9395's uninterruptible power modules
(UPMs) automatically act as N+1 redundant systems.
9395 550 kVA
UPM #1 UPM #2
Key applications
s,ARGEDATACENTERS
s#OLOCATIONFACILITIES
s3ERVERFARMS
s4ELECOMMUNICATION
installations
s)NTERNETSERVICEPROVIDERS
s4RANSPORTATIONSYSTEMS
s3ECURITYOPERATIONS
s"ROADCASTINGAND
entertainment
s0ROCESSCONTROL
equipment
s&INANCIALSYSTEMS
s#REDITCARDOPERATIONS
s(EALTHCARE
s)NDUSTRIALSYSTEMS
s-ULTIPLEMEDICALIMAGING
units