Datasheet

Note Overload cycle for 60 s every 600 s
Note at 400 V, 50 Hz
150 % Overload P kW 4
Note at 440 - 480 V, 60 Hz
150 % Overload P HP 5
maximum permissible cable length I m screened: 100
screened, with motor choke: 200
unscreened: 150
unscreened, with motor choke: 300
Apparent power
Apparent power at rated operation 400 V S kVA 6.58
Apparent power at rated operation 480 V S kVA 7.9
Braking function
Standard braking torque max. 30 % MN
DC braking torque max. 100% of rated operational current I
e,
variable
Braking torque with external braking resistance Max. 100% of rated operational current Ie with external braking resistor
minimum external braking resistance R
min
120
Switch-on threshold for the braking transistor U
DC
V 780 V DC
Control section
Reference voltage U
s
V 10 V DC (max. 10 mA)
Analog inputs 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Analog outputs 1, parameterizable, 0 - 10 V
Digital inputs 4, parameterizable, max. 30 V DC
Digital outputs 1, parameterizable, 24 V DC
Relay outputs 1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Interface/field bus (built-in) OP-Bus (RS485)/Modbus RTU, CANopen®
Assigned switching and protective elements
Power Wiring
Safety device (fuse or miniature circuit-breaker)
IEC (Type B, gG), 150 % FAZ-B16/3
UL (Class CC or J) A 15
Mains contactor
150 % overload (CT/I
H
, at 50 °C) DILM7
DILEM-10
Main choke
150 % overload (CT/I
H
, at 50 °C) DX-LN3-016
Radio interference suppression filter (external, 150 %) DX-EMC34-016
Radio interference suppression filter, low leakage currents (external, 150 %) DX-EMC34-016-L
Note regarding radio interference suppression filter Optional external radio interference suppression filter for longer motor cable
lengths and for use in different EMC environments
DC link connection
Braking resistance
10 % duty factor (DF) DX-BR150-0K5
20 % duty factor (DF) DX-BR150-1K1
40 % duty factor (DF) R:2 x DX-BR100-1K6
Notes concerning braking resistances: R:m = "m" resistors connected in series
The brake resistors are assigned based on the maximum rated power of the
variable frequency drive. Additional brake resistors and designs (e.g. different duty
cycles) are available upon request.
Motor feeder
motor choke
150 % overload (CT/I
H
, at 50 °C) DX-LM3-011
Sine filter
150 % overload (CT/I
H
, at 50 °C) DX-SIN3-010
All-pole sine filter
150 % overload (CT/I
H
, at 50 °C) DX-SIN3-013-A
06/16/2021 Eaton 185733 ED2021 V80.0 EN 3 / 6