Information
Table Of Contents
- Titel
- Inhaltsverzeichnis
- Leistungsübersicht
- PowerXL Drehzahlstarter DE1
- PowerXL Frequenzumrichter DC1 Compact Machinery Drive
- PowerXL Frequenzumrichter DA1 Advanced Machinery Drive
- PowerXL Frequenzumrichter DG1 General Purpose Drive
- Zubehör und Projektierung
- 9000X Frequenzumrichter SVX, SPX
- Softstarter DS7
- Softstarter S801+/S811+
- Dezentrales Antriebssystem Rapid Link 4.0
- SmartWire-DT
CA04020001Z-DE-INT www.eaton.eu
Frequenzumrichter
DE1, DC1, DA1, DL1, DG1, SVX, SPX
9000X
DA1 DL1 DG1 SVX SPX
- - - - -
200 (-10%) - 240 (+10%) - - - -
200 (-10%) - 240 (+10%) - 208 (-15%) - 240 (+10%) - -
380 (-10%) - 480 (+10%) 380 (-10%) - 480 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%) 380 (-15%) - 500 (+10%)
500 (-10%) - 600 (+10%) - - - -
- - - 525 (-15%) - 690 (±10%) 525 (-15%) - 690 (±10%)
- - - - -
- - - - -
4,3 - 248 - 3,7 - 312 - -
2,2 - 450 9,5 - 72 2,2 - 310 2,2 - 245 2,2 - 1940
2,1 - 150 - - - -
- - - 3,2 - 170 3,2 - 1900
-/150 -/150 110/150 110/150 110/150
- - 200 - -
- - - - -
200 200 - - -
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ - -
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ - ✓
✓/✓ ✓/✓ ✓ bei I
H
/✓ bei I
L
✓ bei I
H
/✓ bei I
L
✓ bei I
H
/✓ bei I
L
- - - - -
0,75 - 75 - 0,75 - 75 - -
0,75 - 250 4 - 37 0,75 - 160 0,75 - 132 0,75 - 900
1,1 - 90 - - - -
- - - 2,2 - 160 2,2 - 1800
0 - 50/60 (max. 500) 0 - 50/60 (max. 500) 0 - 50/60 (max. 400) 0 - 50/60 (max. 320) 0 - 50/60 (max. 320)
einstellbar 4 - 32 (hörbar) einstellbar 4 - 32 (hörbar) einstellbar 1 - 12 (real) einstellbar 1 - 16 (real) einstellbar 1 - 16 (real)
IP20/NEMA 0, IP55, IP55/
NEMA 3, IP66/NEMA4X
IP20/NEMA 0, IP55/NEMA 3 IP21, IP54 IP21, IP54 IP00, IP21, IP54
- - - - -10 - +40
-10 - +50 -10 - +50 -30 - +50 -10 - +40/-10 - +50 -10 - +40/-10 - +50
-10 - +40 -10 - +40 -30 - +50 -10 - +40/-10 - +50 -10 - +40/-10 - +50
-10 - +40 - - - -
✓ ✓ ✓ ✓ ✓
-/✓ ✓ ✓ -/✓ -/✓
✓ (FS5 - FS7) ✓ (FS 5 - FS7) ✓ -/✓ -/✓
✓ -/✓ ✓ -/Option -/Option
✓ ✓ - - -
✓ - - ✓ ✓
- - ✓ - -
✓ ✓ ✓ - -
- - - - -
✓ ✓ - - -
- - ✓ - -
Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP,
EtherCAT, BACnet/IP
PROFIBUS, CANopen®,
DeviceNet
PROFIBUS-DP, LonWorks, CANopen®, DeviceNet,
Modbus-TCP, BACnet/IP
optional optional optional - -
1/2 (-10 - +10 V, 0/4 - 20 mA) 1/2 (0 - 10 V, 0/4 - 20 mA) 2 (0 - 10 V, 0/4 - 20 mA) 2 (0 - 10 V, 0/4 - 20 mA) 2 (0 - 10 V, 0/4 - 20 mA)
1/2 (0 - 10 V, 0/4 - 20 mA) 1/2 (0 - 10 V, 0/4 - 20 mA) 2 (0 - 10 V, 0/4 - 20 mA) 1 (0/4 - 20 mA) 1 (0/4 - 20 mA)
4/5 4/5 8 6 6
1/2 1/2 1 1 1
2 (1x Schließer, 1x Wechsler) 2 (1x Schließer, 1x Wechsler) 3 (2x Schließer, 1x Wechsler) 2 (Schließer) 2 (Schließer)
IEC/EN 61800-2, IEC/EN 61800-3, IEC/EN 61800-5
CE, UL, cUL, RCM, UkrSEPRO, EAC CE, UL, cUL, RCM CE, UL, cUL, RCM
DNV - - DNV DNV
RoHS, ISO 9001
5