Information

Table Of Contents
120 Softstarter S801+, S811+
CA04020001Z-DE-INT www.eaton.eu
Typschlüssel
UL/CSA
Information relevant for export to North America
S801+N…, S801+R…, S801+T… (600 V) S801+U…, S801+V... bis 850 A (600 V)
S811+N…, S811+R…, S811+T… (600 V) S811+U…, S811+V... bis 850 A (600 V)
Product Standards IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking
UL File No.
E202571 E202571
UL CCN
NMFT NMFT
CSA File No. LR 353 LR 353
CSA Class No.
3211-06, 2411-01 3211-06
NA Certification UL Listed, CSA Certified UL Listed, CSA Certified
Conditions of Acceptability
None None
Suitable for
Branch Circuits, not as BCPD Branch Circuits, not as BCPD
Max. Voltage Rating 600 Vac 600 Vac
Degree of Protection
IP20 with kit IP20 with kit
S811+…V3S (690 V)
Product Standards
IEC/EN 60947-4-2; UL 508; CE marking
UL File No.
E202571
UL CCN NMFT
CSA File No.
CSA Class No.
NA Certification UL Listed
Conditions of Acceptability
None
Suitable for
Branch Circuits, not as BCPD
Max. Voltage Rating 690 Vac
Degree of Protection
IP20 with kit
S
801+
N
66
N
3
S
N = 65 mm
R = 110 mm
T = 200 mm
U = 200 mm
V = 290 mm
37 = 37 A
66 = 66 A
10 = 105 A
13 = 135 A
18 = 180 A
24 = 240 A
30 = 304 A
36 = 361 A
42 = 420 A
50 = 500 A
65 = 650 A
72 = 720 A
85 = 850 A
Version
S = Softstarter
Ausstattung
Bemessungsbetriebsstrom I
e
Anzahl Pole
N = Grundgerät (S801+/S811+)
P = Pumpenalgorithmus (S811+)
V = 690-V-Netz (S811+)
3 = 3-poliges Gerät (3-phasig gesteuert)
S = Standardversion
Version
801+ = mit Einstellelementen
811+ = mit Bedieneinheit
Baugröße