Data Sheet

DATASHEET - M22-I1MGE-SAL
Surface mounting enclosure, metal, yellow, 1 mounting location
Part no. M22-I1MGE-SAL
Catalog No. 118456
Alternate Catalog
No.
M22-I1MGE-SALQ
Delivery program
Basic function accessories Surface mounting enclosure
Housing Metal
With high-grade steel screws
Number of locations Qty. 1
Cable entry knockouts
Cable entry -
Degree of Protection IP66, IP67, IP69
Colour
RAL Value RAL 1004
Connection to SmartWire-DT no
For use with 1 x ⌀ 22.5
For use with (Illuminated) pushbuttons
(Illuminated) selector switches
Key-operated pushbuttons
Indicator light
controlled stop/emergency-stop buttons with yellow label
Technical data
General
Degree of Protection IP66, IP67, IP69
Design verification as per IEC/EN 61439
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat
and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Please enquire
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
06/16/2021 Eaton 118456 ED2021 V80.0 EN 1 / 2