Datasheet
EATON RF SYSTEM
61
Configuration possibilities
The configurations specified here are just a few examples. Other combinations are of course possible, too.
1. "Heating actuator with electrical panel” only, without any assigned sensors
Application: Backup mode = Emergency mode
Real temperature: Internal sensor in the electrical panel
Set-point temperature: Handwheel on electrical panel
Comfort: -
Eco: -
Off: -
2. "Heating actuator for electrical panel" with assigned “Push-button” (binary input M2, remote control,…) allowing to
change the operating mode
Application: When you are absent, the temperature will be reduced, when you are in the house, the
temperature will be increased again
"Present ON"
Set-point temperature: Handwheel on the electrical panel
Real temperature: Integrated temperature sensor in the electrical panel
LED Heating (red): ON when heating is requested
LED ECO (green): OFF
"Present OFF"
Set-point temperature: Depending on the setting in "Operating mode set-point value" (pre-setting is 18°C)
Real temperature: Integrated temperature sensor in the electrical panel
LED Heating (red): ON when heating is requested
LED ECO (green): ON,
Comfort extension can now be activat-
ed (pre-setting 3 hours)
When comfort extension is active, the
set-point temperature of the hand-
wheel on the electrical panel will be
applied.
3. "Heating actuator for electrical panel" with assigned "Room controller for electrical panels", just for specifying the set-
point value
Application: Central set-point specification for several rooms equipped with electrical panels, the real
values can be used from each of the internal sensors in the electrical panels
"Reduction switch RC" DAY
Set-point temperature: Handwheel (+-3°C) and reduction switch (21°C) on the "Room controller for electrical panels"
Real temperature: Temperature sensor integrated in the electrical panel
LED Heating (red): ON when heating is requested
LED ECO (green): OFF
"Reduction switch RC" Night
Set-point temperature: Handwheel (+-3°C) and reduction switch (8°C) on the "Room controller for electrical panels"
Real temperature: Temperature sensor integrated in the electrical panel
LED Heating (red): ON when heating is requested
LED ECO (green): ON,
Comfort extension can now be activated (pre-setting 3 hours)
When comfort extension is active,
the set-point temperature of the
handwheel on the electrical panel
will be applied.