Datasheet
EATON RF SYSTEM
41
Energy Meter Sensor Adapter Plug - Earthing Pin CEMP-01/12
Technical Specifications
Power supply 230VAC, 50Hz
Plug system Earthing pin, with children protection
Power consumption 0.42W
Max. current 16 A
Min. power >3 W
Max. power ≤3680 W
Accuracy 5% for 230W – 3680W (-5 to 45°C)
Units of measurement Energy in Wh
Current in A
Voltage in V
Effective power in W
Pre-protection Power circuit breaker 16A, characteristic C
Frequency 868,300 MHz
Type of transmission Bi-directional, via coded telegrams
Indoor range * Typically 15 - 25m, 1 wall + 1 ceiling
(depending on wall thickness and material !!)
Degree of protection IP20
Degree of soiling 2
Operating temperature -5 to +40°C
Storage /transportation temp. -25 to +70°C
Colour of the frame White, similar to RAL9016
Size of the frame HxWxD - 138 x 60 x approx. 54mm
Approval Printed onto the device
* Information: For technical reasons, the CEMP-01/12 energy meter sensor features
a shorter RF range than usual xComfort standard products. “Routing” the signal
may therefore be necessary in cases where the direct RF range is not sufficient.
However, this does not impair the functionality of the energy meter function and
will not be accepted as a reason for complaint.
Energy Meter Sensor Adapter Plug - Side Earthings CEMP-01/11
Technical Specifications
Power supply 230VAC, 50Hz
Plug system Side earthings, with children protection
Power consumption 0.42W
Max. current 16 A
Min. power >3 W
Max. power ≤3680 W
Accuracy 5% for 230W – 3680W (-5 to 45°C)
Units of measurement Energy in Wh
Current in A
Voltage in V
Effective power in W
Pre-protection Power circuit breaker 16A, characteristic C
Frequency 868,300 MHz
Type of transmission Bi-directional, via coded telegrams
Indoor range * Typically 15 - 25m, 1 wall + 1 ceiling
(depending on wall thickness and material !!)
Degree of protection IP20
Degree of soiling 2
Operating temperature -5 to +40°C
Storage /transportation temp. -25 to +70°C
Colour of the frame White, similar to RAL9016
Size of the frame HxWxD - 138 x 60 x approx. 57mm
Approval Printed onto the device
* Information: For technical reasons, the CEMP-01/11 energy meter sensor features
a shorter RF range than usual xComfort standard products. “Routing” the signal
may therefore be necessary in cases where the direct RF range is not sufficient.
However, this does not impair the functionality of the energy meter function and
will not be accepted as a reason for complaint.