Home Manager CHMU-00/02
Technical Specifications
Power supply 230VAC/50Hz
Power consumption - standby: 6VA (with background lighting
switched off)
Power consumption - normal: 8VA (with background lighting
switched on)
Fine-wire protection in the device T 63 mA
Pre-protection Power circuit breaker 16A,
charateristic C
Frequency 868,300 MHz
Type of transmission Bi-directional, via coded
telegrams
Indoor range Typically 30 - 50m, 2 walls + 1 ceiling
(depending on wall thickness and
material !!)
Degree of protection IP20
Degree of soiling 2
Operating temperature +5 to +45°C
Storage/transportation temp. -25 to +70°C
Colour of the frame Similar to RAL9011
Dimensions of the frame HxWxD - 174 x 186 x 66 mm
Max. length of RS232 10m from the Home-Manager to the
most distant device, for longer
distances use a standard RS232
amplifier, max. distance 30 m. For
indoor-use only.
Back-up battery 3V CR2032 lithium cell
Approval Printed onto the device
Installation
depth