Datasheet

EATON RF SYSTEM
2
EATON RF system
Wiring Examples for Switching Actuator CSAU-01/01
e.g. lamps, pumps,
fans and sound sig-
nal emitters
e.g. heating,
garage door
opener
e.g. electric
sauna
voltage-free
multiphase
Switching fluorescent lamps with a CSAU-01/01 actuator
SA cycles Total capacitor value
55000 25µF
26000 55µF
14000 9F
8000 100µF
7000 130µF
The numbers of SA cycles specified are approximate values and may vary depending on the local conditions prevailing in each case. The
total capacitor value is the sum of the individual capacitor values according to the type and number of fluorescent lamps compensated in
parallel (see table below). The max. load current of the actuator must not be exceeded. The max. number of cycles selected depends on the
type of application and hence determines the number of fluorescent lamps to be switched via an actuator.
Lamp capacity Capacitor / Compensation in parallel
4-13W 2uF
15-40W 4,5uF
58W 7uF
The above mentioned values are given by the manufacturers of fluorescent lamps and ballasts. Subject to changes without guarantee.