User's Guide
Table Of Contents
- EkaNet™ Hardware Manual
- Table of Contents
- List of Figures
- 1. Introduction
- 2. ECR-2400 Node Hardware
- 3. Elster A3/Alpha Plus Node Hardware
- 4. RESI-MON Node Hardware
- 5. Gateway Hardware

RESI-MON Node Hardware
EkaNet Hardware Manual 4 - 6 10156-04
Eka Proprietary and Confidential
Network Specifications
No hard limitation on number of meters per Gateway (actual number of meters per
Gateway depends on network performance requirements)
Full peer-to-peer communication
Fully self-configuring
Automatic routing
No network address management required
Automatic network acquisition
Automatic time synchronization of all nodes in the network
128 bit authentication/encryption
Operating Conditions
Environmental -40°C to +70°C
5 - 95% non-condensing humidity
Power Supply Internal to meter
5 volt DC
Power Consumption 0.5 Watt typical