Specification Sheet

ELECTRICAL DATA
120V 277V
Model Power (W) Current (A) PF Power (W) Current (A) PF
LEM 0.52 0.069 0.06 0.64 0.07 0.03
LEMSD 0.534 0.067 0.07 0.67 0.069 0.04
LEM2 0.92 0.146 0.05 1.02 0.138 0.03
LEM2SD 1.12 0.145 0.06 1.19 0.137 0.03
LEM4SD 1.96 0.25 0.07 1.81 0.21 0.03
LEMRO .58 .076 .064 .79 .077 .037
PHOTOMETRY
LEM/LEM2/LEM4
LEMRO
X Y Z Orient Tilt Roll
-0.25 0.5 7.5 90 7 1
0.25 0.5 7.5 90 7 -1
28.75 0.5 7.5 90 7 1
29.25 0.5 7.5 90 7 -1
57.75 0.5 7.5 90 7 1
58.25 0.5 7.5 90 7 -1
-29.25 0.5 7.5 90 7 1
-28.75 0.5 7.5 90 7 -1
X Y Z
0 0.33 7.5
0.33 0.33 7.5
24.33 0.324 7.5
48.33 0.317 7.5
72.33 0.311 7.5
96.33 0.305 7.5
24 0.323 7.5
48 0.316 7.5
72 0.309 7.5
96 0.302 7.5
calc grid in between fixtures
Illuminance (Fc)
Average = 1.03
Maximum = 1.5
Minimum = 0.2
Avg/Min Ratio = 5.15
Max/Min Ratio = 7.50
Spacing Stat Area
calc grid in between fixtures
Illuminance (Fc)
Average = 1.03
Maximum = 1.5
Minimum = 0.2
Avg/Min Ratio = 5.15
Max/Min Ratio = 7.50
Spacing Stat Area
29ft
Luminaire Schedule
Symbol
Qty
Label
Arrangement
Total Lamp Lumens
LLF
Description
8
WahChun
SINGLE
N.A.
0.912
LEM
Luminaire Location Summary
LumNo
Label
X Y Z
Orient Tilt
Roll
22
WahChun
-0.25 0.5
7.5
90
7
1
23
WahChun
0.25 0.5
7.5
90
7
-1
24
WahChun
28.75 0.5
7.5
90
7
1
28
WahChun
29.25 0.5
7.5
90
7
-1
29
WahChun 57.75
0.5
7.5
90
7
1
30
WahChun
58.25 0.5
7.5
90
7
-1
31
WahChun
-29.25 0.5
7.5
90
7
1
32
WahChun
-28.75 0.5
7.5
90
7
-1
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.05 0.11 0.22 0.45 0.74 1.05 1.18 1.16 1.18 1.18
1.13
1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11 1.14 1.17
1.20 1.24 1.21 1.19 1.05 0.76 0.47 0.28
0.23
0.28
0.46 0.76 1.04 1.22 1.21
1.11
1.12
1.13
1.10 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.10
1.11
1.13 1.13
1.12 1.24 1.24 1.06 0.77 0.47 0.28 0.22 0.27 0.47 0.76 1.07
1.17
1.20 1.24 1.20 1.16
1.13
1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09 1.12
1.15
1.18 1.19
1.17
1.21 1.08 0.76 0.47
0.27 0.22 0.28 0.47 0.77 1.06 1.21 1.16
1.14 1.15 1.14 1.11
1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11
1.16 1.20 1.24 1.22
1.17
1.06 0.76 0.44
0.23
0.11 0.05 0.02 0.01 0.010.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01
0.03
0.06 0.14 0.28 0.56 0.94
1.30
1.44
1.30
1.25 1.20
1.15 1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11 1.14
1.19 1.22 1.27
1.33 1.39 1.34
0.94 0.59
0.36 0.30 0.3
6
0.58 0.96
1.32
1.47
1.38
1.18
1.17 1.15
1.12 1.09 1.08 1.07 1.06 1.06 1.07 1.08 1.12
1.13
1.15 1.17
1.19
1.37
1.47
1.34
0.96 0.59
0.36
0.28
0.35
0.59 0.96
1.33 1.38 1.33
1.27 1.22
1.17
1.13
1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.13
1.16 1.20 1.25
1.31
1.44
1.31
0.95 0.59
0.35
0.28
0.36
0.59 0.94
1.37 1.39
1.29 1.20 1.18 1.16 1.12 1.10 1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11
1.16 1.21 1.25 1.28
1.32
1.28 0.95 0.550.29 0.14 0.06
0.03
0.01 0.010.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01
0.03
0.06 0.14 0.28
0.53
0.85 1.16
1.34
1.29 1.26 1.22
1.17
1.12 1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11 1.14
1.19
1.23
1.28 1.27 1.27 1.19 0.87 0.57
0.35 0.30 0.3
5
0.55 0.87
1.14
1.33 1.33
1.22 1.19
1.17 1.14 1.11
1.08 1.07 1.06 1.06 1.07 1.08 1.12
1.15 1.17
1.19 1.21 1.28
1.31
1.17
0.87 0.56
0.35
0.28
0.35
0.55 0.87
1.15
1.29 1.29 1.29 1.24 1.19
1.13
1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.13
1.18 1.22 1.25 1.28
1.30
1.17
0.86 0.56
0.34
0.28
0.35
0.54 0.86 1.18
1.30 1.31 1.23
1.20 1.18
1.14 1.11
1.09 1.08 1.07 1.07 1.07 1.08 1.09
1.11
1.16 1.22 1.26 1.25
1.23
1.14
0.85 0.520.28 0.14 0.07
0.03
0.01 0.010.00 0.00 0.00
0
5
10
15
20 25
30 35
40
45
50
55
60 65 70
75
80 85 90 95 100 105-105 -100 -95 -90 -85 -80
-75
-70 -65 -60
-55
-50
-45
-40
-35 -30
-25 -20
-15
-10
-5
0
3ft
24ft
29 ft
ALL POINTSALL POINTS
1.0
1.0
1.1
1.3
1.61.0 0.80.7 0.80.8
1.3
1.7
1.2 1.0 1.0 0.9 1.0 1.0
1.1 1.4
1.6 1.0 0.8 0.7 0.8 0.8
1.3
1.7
1.2 1.0 1.0 0.9 1.0 1.0
1.1 1.4
1.6 1.0 0.8 0.7 0.8 0.8
1.3
1.7
1.2
1.2
1.2
1.4 1.7
2.0
1.4
0.90.8 0.8
1.1
1.8 2.0
1.5
1.3
1.2
1.1
1.2 1.2
1.4 1.7
2.0
1.4
0.9 0.8 0.8
1.1 1.7
2.0
1.5
1.3
1.2
1.1
1.2 1.2
1.4 1.7
2.0
1.4
0.9 0.8 0.8
1.1 1.7
2.0
1.5
0.5
0.5 0.5 0.70.8 0.80.5 0.40.5 0.6 0.8 0.7 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.7 0.8 0.8 0.5 0.4 0.5 0.6 0.8 0.7 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.7 0.8 0.8 0.5 0.4 0.5 0.6 0.8 0.7 0.6
1
Orient: 90
Tilt: 16
Roll: 10
.1
2
Orient: 90
Tilt: 16
Roll: -10
.1
49
Orient: 90
T
ilt: 16
Roll: -1
0
.1
50
Orient: 90
Tilt: 16
Roll: -10
.1
51
Orient: 90
Tilt: 16
Roll: -10
.1
52
Orient: 90
Tilt: 16
Roll: -10
.1
53
Orient: 90
Tilt: 16
Roll: 10
.1
54
Orient: 90
Tilt: 16
Roll: 10
.1
55
Orient: 90
Tilt: 16
Roll: 10
.1
56
Orient: 90
Ti
lt: 16
Roll: 10
.1
24ft
***The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The
corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture
mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid,
not as guarantee of any code compliance.
PathLinx LED Emergency Light
LEMRO
LEM
LEM2/LEM4