34003906EN_AE.fm Page 1 Vendredi, 19. décembre 2008 1:49 13 www.eaton.
34003906EN_AE.fm Page 2 Vendredi, 19.
4003906EN_AE.fm Page 3 Vendredi, 19. décembre 2008 1:49 13 The Network Management Card & Modbus/Jbus (66103) is recommended for central UPSs protecting entire networks or for UPS units backing up critical loads.
34003906EN_AE.fm Page 4 Vendredi, 19. décembre 2008 1:49 13 .
34003906EN_AE.fm Page 5 Vendredi, 19. décembre 2008 1:49 13 The Network Management Card & Modbus/Jbus (66103) can be hot-plugged on all UPSs from EATON equipped with a Minislot. It is not necessary to shutdown the UPS, disconnect the load or restart the UPS. ● Remove the plastic cover of the Minislot. ● Note the MAC address of the card before inserting it. Settings/ Sensor ASI 100M 10M UPS data RS232 66103 ETHERNET ● Insert and secure the card with the screws. ● Connect the ETHERNET cable.
34003906EN_AE.fm Page 6 Vendredi, 19. décembre 2008 1:49 13 Your network is equipped with a BOOTP/DHCP server (default) The card is configured by default with this service enabled. No manual configuration is required.The IP parameters are automatically collected by the card. From the main configuration menu: (see above) ● Press the 2 key (Network configuration). ● Press the 1 key(Read Network settings).
34003906EN_AE.fm Page 7 Vendredi, 19. décembre 2008 1:49 13 ACCESS TO SUPERVISION To check whether the Network Management Card & Modbus/Jbus (66103) is operational after installation and configuration, proceed as follows. ● Run a browser ● Enter in the address bar: http://IP address/ (e.g. http://172.16.1.82/) ● The home page is displayed ● Set the time by clicking the Time command. ● Continue configuration via the sections in the Settings menu.
34003906EN_AE.fm Page 8 Vendredi, 19. décembre 2008 1:49 13 SENSOR CONNECTION (option) ETHERNET The Environment sensor is a Network Management Card & Modbus/Jbus option. It is available from EATON (cat. no 66846). The sensor remotely monitors the UPS environment by regularly measuring the temperature and humidity, and checking the states of two external contacts. It can also send alarms (e-mail, SNMP trap) tripped by pre-set thresholds.
34003906EN_AE.fm Page 9 Vendredi, 19. décembre 2008 1:49 13 JBUS/MODBUS RS232 link configuration and connection SA1 SA2 Pin Function 4 SG 3 2 1 Txd SA2 Received data (input) Not connected Transmitted data (output) Not connected Signal ground 1 8 OFF ON 5 1 2 3 4 5 Rxd RS485 link configuration and connection For proper operation, the polarity of EIA RS485 2-wire and 4-wire lines must be set at only one point and the lines terminated at the end.
34003906EN_AE.fm Page 10 Vendredi, 19.
34003906EN_AE.fm Page 11 Vendredi, 19.
34003906EN_AE.fm Page 12 Vendredi, 19.
34003906EN_AE.fm Page 13 Vendredi, 19. décembre 2008 1:49 13 ● Press the 2 key (Modifiy Jbus settings) ● Press «Return» key to modify the Jbus settings Setting Jbus configutration Set Slave number : 0x1* Set the Baud Rate [1:38400,2: 19200, 3:9600, 4: 4800, 5: 2400, 6: 1200] :3 Set data format[1: 8 bits, 2: 7 bits] :1 Set stop bit[1: 1 bits, 2: 2 bits] :1 Set parity [1: None, 2: Even, 3: Odd] :1 Wait during the new setting is saved ... TLS/Slave JBUS initialized The Jbus configuration is now updated.
34003906EN_AE.fm Page 14 Vendredi, 19. décembre 2008 1:49 13 TECHNICAL CHARACTERISTICS Physical characteristics Dimensions (W x D x H) 132 x 66 x 42 mm Weight 70 g RoHS 100% compatible Storage Storage temperature range -10°C to 70°C Ambient conditions Operating temperature range 0°C to 40°C Relative humidity 90% RH max. without condensation Card performance Supply voltage 5V ±5% Supply current (all LEDs ON and Environment Sensor connected) 300 mA max.
34003906EN_AE.fm Page 15 Vendredi, 19. décembre 2008 1:49 13 ELECTROMAGNETIC COMPATIBILITY When correctly installed and used in accordance with manufacturer instructions, the card complies with the following standards: ● ITE (Information Technology Equipment) safety: IEC/EN 60950-1 2002 ● EMC: EN 61000-6-2 (2002), EN 61000-6-3 (2002), IEC/EN 62040-2 (2002) In compliance with European directives: ● Low voltage: 73/23/EEC and 93/68/EEC. ● EMC: 89/336/EEC and 93/68/EEC.
34003906EN_AE.fm Page 16 Vendredi, 19. décembre 2008 1:49 13 www.eaton.