Users Manual

2 Characteristic
All MIN/MAX specification limits are guaranteed by design, production testing and/or statistical characterization. Typical
values are based on characterization results at default measurement conditions and are informative only.
Default measurement conditions (unless otherwise specified): VBAT= 3.0 V, TA = 25 oC. All radio measurements are done
with standard RF measurement equipment.
3 Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are
stress ratings only, so functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specification are not implied.
Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability.
Table 2: Absolute Maximum Ratings
Parameter
Conditions
Min
Max
Unit
V
BAT_LIM
-0.1
3.6
V
4 nRecommended Operating Conditions
Table 3: Recommended Operating Conditions
Parameter
Description
Conditions
Min
Typ
Max
Unit
V
BAT
battery supply voltage
enabling FLASH
programming
1.65
3.3
V
V
PIN
voltage on a pin
-0.1
3.3
V
T
A
ambient operating
temperature
-40
27
85