EasyWeld EasyCT 213/312 Multipurpose Tig / Plasma Cutter Operation Manual Hong Kong EasyWeld Limited 1
Introduction The EasyCT series of Welders is a revolutionary new approach to Welding technology. Easyweld introduced a more efficient way to manufacture top quality machines while keeping the cost of operation and repairs lower. This was accomplished using several new approaches to the mainstream technology.
CONTENTS - Warning 4 - General Description 5 - Main Parameter 6 - Installation 7 - Operation 9 - Caution 9 - Maintenance 10 - Troubleshooting 10 3
WARNING Welding and cutting is dangerous to the operator, people in or near the working area, and the surrounding, if the equipment is not correctly operated. Therefore, the performance of welding/cutting must only be under the strict and comprehensive observance of all relevant safety regulations. Please read and understand this instruction manual carefully before the installation and operation.
GENERAL DESCRIPTION This welding & cutting equipment is manufactured with advanced inverter technology. With power component MOSFETS and by adopting PWM technology, the inverter converts DC voltage which is rectified from input AC voltage to the high 100KHz frequency AC voltage; as a consequence, the voltage is transformed and rectified.
MAIN PARAMETER TYPE Input Voltage (VAC) Input Frequency (Hz) Consumption (KVA) No-load Loss (W) Duty Cycle (%) Power Factor Efficiency (%) Insulation Class Protection Class Weight (Kg) Size(mm) Input Current (A) Output Current (A) Current Range (A) No load Voltage (V) Working Voltage (V) Nozzle Internal (mm) Air Pressure (MPa) Gas Flow (L/min) Applicable Thickness(mm) Arc-Starting EasyCT 312 220±15% 50/60 3.5 40 60 0.93 85 B 1P21 8 395 × 163 × 290 TIG PLASMA MMA 10.2 16 15.
INSTALLATION Main Current Power Switch Pilot Lamp Power Lamp Compress Air Gas Inlet Function Switch Ground Connection Electrode Holder Connection Argon Gas Inlet Torch 2-pin Socket Compress Air Gas Regulator Torch Connection CT-312 Main Current Pilot Lamp Power Lamp Power Switch Function Switch Torch Connection Argon Gas Inlet Torch 2-pin Socket Ground Connection CT-213 Compress Air Gas Regulator Compress Air Gas Inlet 1.
earth clamp with work piece. 2d. The electrode holder cable should normally be connected to the positive terminal, while the work piece should be connected to the negative terminal. 3. Power Supply Switch In case that power switch is on, built-in fan start work and current meter displays the current value. 4. Function Switch Function switch enables the option among MMA, TIG and CUT according to practical welding task requirement. 4a.
OPERATION 1. TIG Welding Function 1) While this welding & cutting equipment is operated, power supply indicator is on, and the built-in fan is functioning. 2) Opt the TIG welding function mode. 3) Press the gas-releasing button, and modulate the volume of gas output to the required value. 4) Press the button of welding torch, and the electromagnetic valve functions. The sound of electricity releasing is audible and there is gas out from welding torch.
environment should be maintained within -10°C to +40°C. 1.3 Keep this welding & cutting equipment 30cm distant from the wall. 1.4 Keep the working environment in good ventilation. 2. Safety tips 2.1Ventilation This welding & cutting equipment is small-sized, compact in structure and of excellent performance in current output. Fans are required to abstract heat generated by this cutting equipment while the operation of welding is carried out.
and compensate it if necessary. 2. While this welding & 1. Possible misconnection with input of 380V, and cutting equipment is occurrence of over voltage protection status. operated, the pilot Reconnect with input of 220V, and restart. lamp is on, no output, 2. Possible unstable input due to the un-available the built-in fan input cable or possible connection unavailable unavailable. spells it’s being of over-voltage protection status. 3.
4. Components of HF arc starting circuit are possibly damaged. Check and replace them if necessary. 6. While this welding & 1. It is possible of over-current protection status. cutting equipment is Switch off the power supply, wait till the fault operated, the fault indicator is off, and restart this welding indicator is on, and equipment. there is no output. 2. It is possible of over-heating protection status. Wait till the fault indicator is off, and the welding operation will be available. 3.