Specifications

14
EasyCut 60/100 Problems and Solutions
Breakdown Solution
Power switch is turned on but no
activity, no fan and no lights.
1. The assistant transformer on
the control board is broken.
2. The power input wires are not
connected properly.
3. Wires or connectors have come
loose inside the machine.
Power switch is on, fan comes on
but when pressing the torch button
no arc starts and the error LED
comes on.
1. The rectifier diode is damaged
2. The high frequency capacitor
1KV/102 is broken
3. K1170 on the top board is
broken.
4. The step-up transformer on the
bottom board is broken
5. The control model is broken
The power switch is in the ON
position and the fan works. When
pushing the cut button on the torch
the valve opens and allows air to
pass but no arc starts and the error
LED does not come on.
1. The torch consumables are
improperly installed.
2. The primary coil of the
arc-leading transformer is
shorted or not well-connected.
3. The rectifier diode(s) is
damaged.
4. The HF capacitor is leaking.
5. The relay(s) is damaged.
The arc doesn’t start when I push
the torch button.
1. Low input voltage.
2. The air compressor pressure is
too low or too high.