Operation Manual

5
3. SET VIEW / FUNCTION ELEMENTS
1. Function switch
Position Information
OFF Device is switched off
PROG Entering of calling numbers, calling number sequence, PIN-Code and further parameters
ON Device is in supervision mode
2. Selection switch
EasyAlarm
®
monitors depending on the position of the selection switch
Position Monitoring functions (Function switch on position ON)
I Wired sensor-1 enabled. Acoustical monitoring disabled!
II Wired sensor-1 enabled. Acoustical monitoring disabled!
III Wired sensor-1 enabled. Acoustical monitoring enabled with highest sensitivity => Alarm is triggered if
noise level is exceeded two or three times within a short period
Note: Monitoring functions can be modified individually according to section 5.4ff!
3. Keypad
When function switch is on position PROG, you can enter the calling numbers or do further programming. If function
switch is on position ON pressing any key will start a test call.
Keys are marked with 1 2 3 4 5 6 7 8 9 * 0 # .in the following sections.
4. Loudspeaker
The integrated loudspeaker is used for voice guidance during the programming as well as for hands-free communication
during phone connection.
5. Microphone
Is used during hands-free connection and for recording of individual message.
6. LED
Status of LED Operation mode
Green Waiting period
Green brief flashing every 4 seconds, also if acoustical
monitoring is active by exceed set noise level
Supervision mode activated
Green is on and off for 4 seconds alternatively Supervision mode deactivated
Orange Phone connection
7. Battery compartment
The 9V-battery is used as a backup during power failure.
Please note: The telephone cord must be disconnected before opening the battery
compartment because otherwise you can get in contact with the telecommunication voltage!
8. Telephone jack (-LINE)
The plug must be locked in the jack. To disconnect press pawl.
9. External ports (EXT/≂) for accessories (as motion sensor) and power supply.
6
1
5
4
3
2
-LINE
EXT/
~