14. OVERVIEW
Indicator (LED)
Supervision mode without acoustical monitoring
Supervision mode with acoustical monitoring
Supervision mode inactive
During phone connection
Alarm independent of alarm unit state (armed or disarmed)
active on„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Emergency (Sensor-2)
2)
Delayed Hands-free connection „Emergency call activated“
Sensor-3
3)
Un-delayed Listening-in connection „Alarm due to sensor 3“
1.) Default values without en without consideration of user specific programming in accordance to section 5
2.) Emergency call activation according to section 5.2.2: An emergency call will be triggered, if the button has been
activated for one second. After a pre alarm period of 20 seconds EasyAlarm
®
starts dialling calling number(s) and a
hands-free connection is established. During the pre warning period the alarm can be cancelled by pressing the
emergency button respectively by pressing key 0 .
3.) Sensor-3 activation according to 5.3.1.
Alarms only if alarm unit is armed
active on
„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Sensor 1
4)
Un-delayed Listening-in connection „Alarm due to sensor 1“
Presence verification
5)
10 Minutes/30
Seconds
Hands-free connection
“Alarm due to presence
verification”
Sensor 2
6)
Un-delayed Listening-in connection „Alarm due to sensor 2“
Noise (Babyphone)
7)
Un-delayed Listening-in connection „Alarm due to noise“
Mains power loss
1 Minute Hands-free connection „Alarm due to power failure “
4.) Sensor-1 activation according to 5.1.1.
5.) Sensor-1 can be used to verify if a person is present ( section 5.1.2), i.e. an alarm will be triggered if no motion is
detected within 24h. Before starting the alarm there is a pre warning period of ten minutes. If activation is detected
(motion detected or emergency button pressed) within this period, the alarm is cancelled, otherwise EasyAlarm
®
establishes a hands-free connection
6.) Sensor-2 activation according to 5.2.
7.) Noise monitoring according to 5.4: To avoid false alarm while acoustical monitoring, close windows and try to
eliminate sources of noise.
8.) EasyAlarm
®
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes (=> time-out
according to section 10.4). During a pre warning period of 1 minute the following message is announced „Alarm due
to power failure“. After this period EasyAlarm® dials the programmed number and a hands-free connection is
established. If EasyAlarm® does not detect mains power during start up the monitoring remains inactive => „Power
failure“ is announced ! As soon as mains power is detected, EasyAlarm® starts to supervise mains power
Alarm release renewed
After an alarm EasyAlarm® remains inactive during a waiting period of two minutes. Only if at expiration of this
waiting period an alarm event occurs again, a new alarm is released. After an alarms through to sensor-1/2/3 a renewed
alerting comes off only if to the alarm contact returned to the state of rest.
Tone-dialling commands
DTMF => Every valid command will be signalled
0 Terminate phone connection and acknowledge alarm
1 Switching to hands-free mode and restart connection time-out
2 Repeat announcements (Individual message / Cause of alarm)
3 Restart connection time-out (2 minutes)
4 Deactivate output (i.e. switching off alarm siren)
5 Announcement of current supervision mode as well as condition of the output
6 Activate output (i.e. switching on the alarm siren)
7 Change to inactive supervision mode (I, II, III) => monitoring for noise, sensor-1, sensor-2, mains failure and
presence verification inactive. Emergency call and sensor-3 alarm are still possible.
8 Terminate phone connection without acknowledgment
9 Change to active supervision mode (I, II, III) => All monitoring functions re-activated
Noise
Nois
4 seconds
4 seconds
4 seconds 4 seconds
Telephone connection