Operation Manual
3
1. INTRODUCTION
EasyAlarm
®
is an easy to use and reliable auto-dialler including announcement unit that can be used in many ways. The
most important functions are listed below. Please read the instruction manual carefully before you start installation.
Especially pay attention to the safety notes.
EasyAlarm is a reliable monitor
Cause of alarm Notes
Noise* Sensitivity I / II / III (LOW / MED / HIGH)
Keystroke Check call / emergency call
Wired sensor input 1*+ Potential separated sensor contact (NO/NC configurable)
=> possibility to trigger an alarm, if an expected repeated action fails
Wired sensor input 2*+ Potential separated sensor contact (NO/NC configurable)
Wired sensor input 3* Potential separated sensor contact (NO/NC configurable)
Technical states / condition
Failure of main supply
Battery condition
*Alarm delay selectable
+ individual announcement or a single stroke bell can be activated
EasyAlarm calls automatically
Destination Notes
Telephone / mobile phone Connection states Listing in: changeover to hands free on demand
Alarm with hands free connection
Pager Numeric alarm message
Alarm centre With protocol Point ID/Contact ID
Alarms up to nine pre programmed phone numbers
EasyAlarm indicates
Indication Notes
Individual announcement Up to 12 seconds duration, at the beginning of connection
Cause of alarm Cause of alarm (periodical announcement)
State of sensor
Technical state / condition Battery condition
EasyAlarm puts you in contact
Mode of contact Notes
Listening in During connection you can listen into the monitored room
Speaking You can talk to a person any time by changing to hands free mode
EasyAlarm provides security
Security steps Notes
Alarm acknowledgement Without acknowledgement you can program up to nine alarm repetitions
Alarm forwarding Without acknowledgement an alarm will be forwarded to next programmed
number
Check call Remote access with PIN code (4 to 7 digits) at any time
EasyAlarm is a telecontrol system
Actions / Reactions Notes
Activation / deactivation of sensors Wired alarm-sensors can be activated or deactivated at any time during
connection mode
Automatic activation of output By triggering of an alarm an output (i.e. siren) can be switched on
automatically, or during connection mode using tone-dialling command
Remote activation of output In connection mode (tone-dialling command) the output can be switched to
drive for example a heater or air-condition unit
Remote programming: alarm number
and alarm-sequence
Alarm number and alarm-sequence can be changed during connection mode,
using tone-dialling commands