Operation Manual

20
8. USEFUL NOTES
8.1 Tone-dialling command
If you want to use EasyAlarm® to its full potential a tone-dialling telephone is necessary. Nowadays most of the
telephones in use are working on tone dialling, also called DTMF or in-band signalling. Older telephones are using pulse
dialling. In case there is no tone-dialling telephone available, the features shown in section 7.7.3 cannot be used
Note:
An acoustic coupler can be purchased in electronic shops.
8.2 User information
8.2.1 Signals (beeps)
A single beep tone is used as a confirmation
Three beep: Mains power loss AND battery low at the same time!
8.2.2 Announcement audible in loudspeaker of EasyAlarm®
Announcement Message / Cause
„Individual message“ First message in case of an alarm
Abort Disconnection caused from the change of the position of the selection switch
Alarm due to presence
verification
Triggered emergency call due to loss of presence
Alarm acknowledged Disconnection
Battery error Battery is low => battery test after power on
Calling number n Calling number n (=1..9)
Calling number error First calling number in the calling number sequence is not programmed
Calling number sequence Calling number sequence
Emergency call activated Emergency call, initiated by emergency button
Emergency call deactivated,
alarm acknowledged
Emergency call confirmed
Error Incorrect programming => the old value remains stored
Line check error Telephone line check after power on was negative => dial tone missing
Output activated The output is activated after power on.
PIN Request to enter PIN-Codes by locked programme
Power failure Mains power missing => Mains power is tested after switching on the unit
Presence verification activated Motion sensor is set to presence verification
Programming deactivated: PIN Request to enter PIN-Code to unlock programming
Supervision (I/II/III) <due to
noise/sensor n> activated
Announcement of the monitored alarm functions at current position of the selection
switch (I/II/III) triggered by pressing key 5. during the inactive waiting period(
section 7.3.1.1)
Supervision (I/II/III) activated Announcement in active supervision mode at current position of the selection switch
(I/II/III)
Supervision (I/II/III) deactivated Announcement in active supervision mode at current position of the selection switch
(I/II/III)
to modify press * , to stop press # Recording of individual message
Unacknowledged alarms: n Quantity of unacknowledged alarms
8.2.3 Announcements audible in the handset of called subscriber
as well as during hands-free connection in loudspeaker of EasyAlarm®
Announcement Message / Cause
„Individual message”
First message in case of an alarm or reaction on DTMF 2 .
Abort Phone connection will be terminated
Alarm due to noise Alarm triggered by noise activity (Note: according to selection switch position
I,II,III the alarm can be delayed)
Alarm due to presence
verification
Triggered emergency call due to loss of presence
Alarm due to programming A test call was initiated due to remote programming ( section 10.8.2)
Alarm due to sensor n
sensor n activated
sensor failure
Reason of alarm: alarm contact n.
sensor n is in alarm mode
disconnection of sensor during operation
Battery error Battery is low => battery test before phone connection is established
Emergency call activated Emergency call, initiated by emergency button
Emergency call due to sensor Emergency call triggered due to loss of presence verification
Output <activated / deactivated>
confirmation of < DTMF 6 / DTMF 4 > ( section 11.4)
PIN Request to enter PIN-Code after dialling in (remote access)
PIN error, abort Wrong PIN-code => Phone connection terminated
Power failure Mains power loss => Mains power is tested every time before phone connection is
established