Operation Manual
19
7.9 Test call
If alarm unit is switched to ON it is possible to start a test call as follows:
1. Select calling number by pressing key <n> (n= 1. .. 9 )
Announcement: „Calling number <n>“ => If selected calling number is not programmed the message
“Error” will be announced and the first calling number will be dialled instead
2. Wait until hands-free connection is established and speak
3. Terminate phone connection by pressing 0. or slide function switch to OFF
Notes:
After ten minutes phone connection will automatically terminate if called party does not give any tone-dialling
commands (i.e. called subscriber can disconnect using DTMF 0 or restart timer using DTMF 3 ).
During inactive waiting period after power on key 9. and 7. activate or deactivate the monitoring of the
supervision. Key 5. starts the announcement of the current supervision mode.
The volume of hands-free connection can be adjusted as described in section 7.7.4.1
7.10 Dialling-in (check call)
If the alarm unit is switched to ON you can dial in from any telephone set as follows:
1. Dial phone number of the EasyAlarm®
2. Let it ring for two ringing cycles and disconnect (hang up)
3. Redial after 20 seconds => EasyAlarm® answers call after two ringing cycles and waits for the PIN-Code
After entering the correct PIN-Code EasyAlarm® establishes a listening-in connection
Announcement „to stop press 0, to speak press 1“
If no tone-dialling command is entered, the phone connection will be terminated after two minutes connection time-out.
The supervised person can also terminate the phone connection by pressing the emergency button.
Important: In case that there are unconfirmed alarms, the quantity as well as the last reason of the alarm will be
announced! An unacknowledged alarm will be confirmed by entering DTMF 0 !
Notes:
The two-step dialling in procedure is for security reasons to avoid detecting of the alarm unit coincidently by an
unknown caller. Direct dialling in as well as other number of ringing cycles can be selected ( section 10.7)
If the PIN-code is incorrect or not entered within 15 seconds, EasyAlarm® disconnects after the announcement „PIN
error, abort“ => try again and enter correct PIN.
PIN-code is factory set to 9797. For safety reasons we recommend changing PIN-code and program your individual
code according to the manual.
If a successful dialling-in should be signalled with five gong-signals (to alert/inform the supervised person),
EasyAlarm® can be programmed according section 10.7.3.
7.11 Answering an incoming call
An incoming call, signalled by a parallel connected phone, can be answered as follows (Function switch ON):
7.11.1 ..by pressing the emergency button
a hands-free connection is established => Disconnect by pressing the emergency button once again.
7.11.2 ..by pressing any key of the alarm unit
a hands-free connection is established => Disconnect by pressing key 0..