LEITRONIC AG Swiss Security Systems TELE-ALARM / TELE-CONTROL User instructions EasyAlarm BASIC® / COMBI® Wired sensors Sensor-connection cord Motion sensor Siren-/Switch module Alarm 5. October 2010 Issue No.: 8.38 EA8-BASIC-COMBI-8-38-GB.
Table of contents 1. Introduction .............................................................................................................................................................3 2. Safety instructions ...................................................................................................................................................4 2.1 2.2 2.3 2.4 3. 4. Set view / Function elements ..............................................................................................
1. INTRODUCTION EasyAlarm® is an easy to use and reliable auto-dialler including announcement unit that can be used in many ways. The most important functions are listed below. Please read the instruction manual carefully before you start installation. Especially pay attention to the safety notes.
2. SAFETY INSTRUCTIONS 2.1 Approval Declaration of Conformity According to the R&TTE Directive 1999/5/EC of 09.March 1999 Manufacturer’s Name: Leitronic AG Manufacturer’s Address: Engeloostrasse 16 CH-5621 Zufikon, Switzerland declares that the product Product Name: EasyAlarm Model Number: EA-8-EXT conforms to the following product specifications: Safety (R&TTE, Article 3.1a): EN60950: 1992+A1+A2+A3+A4 EMC (R&TTE, Article 3.
3. SET VIEW / FUNCTION ELEMENTS 5 3 6 2 4 1 1. Function switch Position Information OFF Device is switched off PROG Entering of calling numbers, calling number sequence, PIN-Code and further parameters ON Device is in supervision mode 2. Selection switch EasyAlarm® monitors depending on the position of the selection switch Position Monitoring functions (Function switch on position ON) I Wired sensor-1 enabled. Acoustical monitoring disabled! II Wired sensor-1 enabled.
4. SETUP 4.1 Operation with Plug&Protect motion sensor (EasyAlarm COMBI) 4.1.1 Safety instructions Function switch must be shifted to OFF and telephone-cord must be disconnected before any wiring work is done on the AC-adapter or Motion sensor cable. All the electrical connections have to be potential free. Observe the regulation according to EN60950.
Select user language / record individual message Details according to section 6.3 12. Slide function switch to PROG 13. Enter *. *. #. Current individual message will be announced followed by “to modify press * , to stop press # “ 14. Select language for user announcements: (facultative) Press key 1 to 4 to select user languages: 1 for German, 2 for French, 3 for English GB, 4 for Italian 15. Press * and start speaking 16. Press # to finish recording, max.
4.2 Operation with potential free alarm contacts (EasyAlarm BASIC) 4.2.1 Safety notes Function switch must be shifted to OFF and telephone-cord must be disconnected before any wiring work is done on the AC-adapter or connecting cable. All contacts of the EXT port are on telephone circuit potential => therefore any applied alarm contact must be potential free (relays or opto-coupler) and must have a isolation of lease 3.75kV according to regulation EN60950.
6. 7. 8. 9. Program calling number(s) Details according to section 6.1 Slide function switch to PROG Enter * * (selected calling number: Standard n = 1..9) Corresponding calling number will be announced, followed by message “to modify press star“ Press * and enter calling number Slide function switch to OFF Select user language / record individual message Details according to section 6.3 10. Slide function switch to PROG 11. Enter *. *. #.
5. CONFIGURATION OF THE ALARM REGISTERS 5.1 Sensor-1 monitoring 5.1.1 Sensor-1 as alarm contact EasyAlarm® auto-detects a Plug&Protect-sensor and starts its monitoring if the system is armed. You can define the behaviour for sensor-1 as following: Example: A normally closed contact shall trigger an un-delayed alarm with a hands-free-connection independent from position of the selection switch. 1. 2. Slide function switch to PROG Enter sequence *. 9. 3. 1. 7 5 6 #. #.. .
5.2 Sensor-2 monitoring 5.2.1 Sensor-2 as alarm contact Alarm function for sensor-2 in armed mode can be selected as following: Example: Sensor 2 is a normally closed contact that should trigger an un-delayed silent alarm on position I/II 1. 2. 3. 4. Slide function switch to PROG Enter sequence *. 9. 3. 1. 7 5 7 #. #.. . Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.“ If you want to keep current value proceed with step 6.
5.3 Sensor-3 monitoring 5.3.1 Sensor-3 as alarm contact Note: if sensor-3 input is enabled as show below, you cannot disarm at any time! Example: A normally closed contact shall trigger an un-delayed alarm with a hands-free-connection independent from position of the selection switch. 1. 2. 3. 4. Shift function switch to PROG Enter sequence *. 9. 3. 1. 7 6 1 #. #.. Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
6. PROGRAMMING Important note: All the programmed parameters remain stored even without battery. You can prevent your system from unintended re-programming according to section 6.4.1. If you use this protection feature message „programming deactivated, PIN“ will be announced when the function switch is on position PROG. Three beep: Mains power loss AND battery low at the same time! 6.1 How to program new calling numbers EasyAlarm® supports nine calling numbers that can be programmed as follows: 1.
6.2 Designation of the calling number sequence 6.2.1 Standard sequence Alarm triggered Calling number 1 Alarm not acknowledged by called party 1 Calling number 2 if called party 3 does not acknowledge the alarm, the calling number sequence is repeated the number of programmed alarm repetitions times (default value: two alarm repetitions, programming see section 10.2) alarm not acknowledged by called party 2 same for calling number 3 to 9 The alarm is acknowledged by pressing DTMF 0 ( section 7.7.5).
6.4 How to program PIN-Code You can change remote access PIN-code as follows: 1. Slide function switch to PROG 2. Press #. You can prevent the alarm unit from unintended programming by pressing * . 3. Enter desired PIN-code (4 to 7 digits!) 4. Press #. 5. Re-enter PIN-code for confirmation 6. Press #. If PIN-code is re-entered correctly it will be announced. If you selected program locking the additional message „programming inactive: PIN” will be announced.
7. OPERATION 7.1 Self check at power on After power on the alarm unit checks battery, mains power and telephone-line conditions. If one of these tests fails an appropriate message will be announced (battery error/power failure/line-check error). Three beep: Mains power loss AND battery low at the same time! Quickly handle the announce problem, otherwise the alarm functions are not guarantied. 7.1.
7.4 Supervision mode LED: acoustical monitoring inactive 4 seconds LED: inactive mode 7.5 Nois Noise LED: acoustical monitoring activated 4 seconds 4 seconds 4 seconds Alarm 7.5.1 .. independent of alarm unit state (armed or disarmed) „Default value“ 1) active on Entry-Delay Connection mode Announcement Cause of alarm I II III 2) Emergency (Sensor-2) Delayed Hands-free connection „Emergency call activated“ Sensor-3 3) Un-delayed Listening-in connection „Alarm due to sensor 3“ 1.
7.7 Phone connection The colour of the indicator LED changes to orange during telephone connection. 7.7.1 Time-out There is a timer running in the phone connection mode. Phone connection is kept up for two minutes in case of alarm call, and ten minutes in case of test call. Ten seconds before disconnection, the called person hears the announcement “abort”. He/she can restart timer using DTMF 3 at any time. 7.7.
7.9 Test call If alarm unit is switched to ON it is possible to start a test call as follows: Select calling number by pressing key (n= 1. .. 9 ) Announcement: „Calling number “ => If selected calling number is not programmed the message “Error” will be announced and the first calling number will be dialled instead 2. Wait until hands-free connection is established and speak 3. Terminate phone connection by pressing 0.
8. USEFUL NOTES 8.1 Tone-dialling command 8.2 User information If you want to use EasyAlarm® to its full potential a tone-dialling telephone is necessary. Nowadays most of the telephones in use are working on tone dialling, also called DTMF or in-band signalling. Older telephones are using pulse dialling. In case there is no tone-dialling telephone available, the features shown in section 7.7.3 cannot be used Note: An acoustic coupler can be purchased in electronic shops. 8.2.
Programming acknowledged Programming, abort Sensor n activated Supervision (I/II/III) < due to noise / sensor n> activated Supervision (I/II/III) activated Supervision (I/II/III) deactivated Unacknowledged alarms: n 8.
9. TROUBLE SHOOTING / ERROR HANDLING Most problems can be checked and solved with help of the following chart. If the problem remains after consulting this chart in details, please get in touch with your local dealer or contact the info line of your country, see section 12.3. 9.
9.2.1 Motion detector activated for presence verification Symptom LED is on during WALK TEST, but no alarm is triggered WALK TEST has been set, but LED is not on Alarming with announcement „emergency call activated, sensor 1 activated “ Alarming with announcement „emergency call activated, sensor failure “ 9.
10. SPECIAL PROGRAMMING Important notes: All parameters remain stored even if EasyAlarm® is switched off or without battery. Therefore reprogramming is only essential if parameters have to be changed. Programming mode can be locked to secure against unintended programming during operation (section 6.4.1). If lock is activated, the announcement „programming inactive: PIN“ will be announced if function switch is shifted to PROG.
10.5.2 .. through external siren Operating mode of the siren can be programmed as follows: OFF ON PROG Value 0 1 2 *. 9. 7. 1. 3 0 7 #. #. Value *. Value #. OFF ON PROG Comment No signalisation by the siren (=factory setting) periodical signalisation of the delay for exit / entry periodical signalisation of the delay for exit / entry permanent siren tone in case of an alarm during listening-in connection (exception: silent panic call) 10.5.3 ..
10.7 Dialling-in (Remote-access) 10.7.1 Program ringing cycles The number of ringing cycles until EasyAlarm® answers the call is defined in register 4 7 : OFF ON PROG Value 0 2..9 *. 9. 7. 1. 3 4 7 #. #. Value *. Value #. OFF ON PROG Comment EasyAlarm® does not answer any call EasyAlarm® answers call after Value ringing cycles (factory setting: Value=2) 10.7.
10.8.2 Remote programming of calling number and calling number sequence If remote programming is enabled calling numbers/sequence can be re-programmed during phone connection: 1. Enter DTMF * * n (n => see chart below) Current calling number/ calling number sequence will be announced. If you want to change, continue at point two. otherwise enter DTMF # . 2. Enter DTMF * 3. Enter new number/sequence After entering of the last digits, wait ten seconds.
11. ACCESSORIES Further accessories can be found on our homepage on www.easyalarm.ch. 11.1Motion / Presence detector-PIR-RJ45 (Plug&Protect) 11.1.1 Preliminary considerations Choose the mounting location after careful consideration of the area to be protected. The motion detector should be located so that an intruder will cross the infrared beam pattern. If used to verify presence, a regular used room should be detected. Figure shows the different infrared beam patterns at a typical mounting height of 2.
11.2 Siren EA-SIR-RJ45 Primary voltage 230 VAC / 50 Hz Secondary voltage: 12 VDC 3 VA Dimension: 120 x 65 x 77mm (L x W x H) Weight: 200 g Length of cable: 3m Installation: connect in place of the BBT-DC12S-RJ45 AC-adapter Functions: A) periodical ton of the siren (during inactive waiting period) B) in case of an alarm in listening-in connection, the siren can be activated permanently C) the siren can be switched on/off during phone connection by entering DTMF 6 / DTMF 4 . 11.
12. SPECIFICATIONS / WARRANTY Changes to product and performance can be made at any time without announcement. 12.1 Specifications 12.1.1 Alarm unit EasyAlarm® EA-8-EXT Supply voltage: Current input: Announcement: Material of housing: Dimensions: Weight: Telephone cord: Calling method: 9..16 V DC (by AC adapter at EXT/≂ connector) Backup: 9V-battery (typical duration of operation about 70 hours) Supervision mode: 7 mA (typical) / during announcement: 55 mA (max.
13. INDEX AC-adapter..........................................6, 8, 9, 28, 29, 30 Accessories ........................................................2, 5, 28 Acoustical monitoring ..................... 5, 12, 16, 17, 23, 32 Alarm... 2, 3, 4, 5, 7, 9, 10, 11, 12, 13, 14, 17, 18, 20, 22, 23, 24, 27, 28, 30, 32 call........................................................................ 18 due to noise ............................... 13, 16, 17, 20, 21, 32 due to power failure.................................