Programming instructions

9
To install run wires from the actuators into control box of the unit. Then connect
the wires to the Pool/Spa valves terminals on top of the board
(See Diagram MVA1).
Make sure you cam the valves correctly
before running water through the system
Operation of
Automation
There are two ways you can operate the
automation:
Use the MODE button on the unit to
switch from Pool to Spa.
Wiring an external switch to the T-Stat
Pool/Spa terminal on top right hand
corner of board
(See Diagram MVA1)
there
is no programming. Activating the external
switch will change the mode and valves from Pool to Spa.
Diagram MVA1
Pump
Filter
Heat
Pump
Plumbing Sequence
The piping sequence is pool pump filter heater chlorination system(s) pool.
Rigid PVC piping is recommended and all joints secured with PVC glue. Installation
MUST conform to all local codes. Make sure water-flow is correct as indicated on back
of heater. Again, try to keep piping away from areas that may be tripped over or
stepped on when operating heater or servicing. Try to keep elbows and piping to a
minimum to avoid excessive pressure drop. We use a full-flow heat exchanger so no
external bypass is needed up to 60 GPM.
Salt Water
Chlorine
Generator
POOL
Installing Motorized Valve Automation To
The Heat Pump.