Product Manual
Table Of Contents
8
Cold Water Electric • Rev. 4/11/2016
PLEASE READ MANUALS CAREFULLY BEFORE USING MACHINE. EXAMINE
MACHINE AND CRATE CAREFULLY FOR SHIPPING DAMAGE OR MISSING
PARTS. REPORT PROMPTLY ANY SHORTAGES OR DAMAGE CLAIMS TO
FREIGHT CARRIER OR DEALER.
OPERATING INSTRUCTIONS
1. Perform pre-start maintenance inspection on all applicable systems prior to operating the
machine. This is essential for the safe, effective and efficient operation. You will get optimum
performance from your system ONLY if these instructions and inspections are followed. Any
indication that the pressure washing system was not operated and maintained according to these
instructions may cancel the manufacturers’ warranty.
Controls – Make sure all controls turned to the off position.
Pump – Oil level - Level the pressure washer. Be sure oil level in the pump is correct on dip
stick. If the level is low, add the correct oil to the proper level. USE ONLY SAE 30 W NON-
DETERGENT OIL OR HYDRAULIC 68. DO NOT OVER FILL.
Visually inspect all electrical components to assure they are in good condition, showing
No signs of exposure, breakage or splicing.
Visually inspect all hoses, nozzles and guns to assure they are in good condition. If
replacements are necessary they must be rated to withstand the machines operating
pressure and temperatures.
2. Attach high-pressure hose to water outlet quick connector. Attach the other end of high
pressure hose (with quick coupler) to spray gun. Ensure that quick disconnect connections are
tightly locked together. Apply a sharp pull on hose to confirm they are secured.
Attach wand nozzle specific to task requirements (i.e. chemical or pressure wash).
[Quick Coupling Operation – Pull back sleeve end and insert male end into nozzle quick coupler,
release sleeve and confirm connection by pulling on nozzle].
3. Attach water source to water inlet located on pump. The water source must be attached with
a good quality standard garden type hose (1/2” minimum is required). Connect male fitting into
the female pump inlet fitting. Make sure that the inlet screen/filter is intact and fitted correctly.
Turn on water source. WATER MUST BE IN SUFFICIENT SUPPLY, AND PRESSURE
MUST BE BETWEEN 20 –60 PSI TO ENSURE PROPER AND SAFE OPERATION. Specific
attention should be given if using a well water supply. Ensure water is flowing from end nozzle
with trigger gun pulled. Deplete system of all air.
4. Start electric motor. Turn PUMP switch to ‘ON’. PUMP switch is located on the frame
beside the motor, or for auto stop/start systems, PUMP switch is located on the electrical box.