4. MAINTENANCE
In many cases, reinstalling system software allows to restore a satellite router functionality
(see Section 3.2), which may need reset to the factory default configuration (see Section
4.2).
If the recovery of software cannot be implemented successfully, or if this operation does not
eliminate the defect, it is necessary to illuminate the faulty device accordingly to the
Section 2.11.4 and replace it by new device.
4.1 Replacement of modules
4.1.1 Common recommendations
Repair of satellite router is carried out by replacing defective units (PSU or a router)
or the whole product.
Replacement must be carried out only on original and compatible units, supplied by
the manufacturer. After replacing the power supply the router is immediately ready
for further operation. In case of a satellite router replacement it has to be
reconfigured to the network parameters in accordance with Section 2.2.
4.1.2 Safety instructions
Repair by replacing blocks of satellite router must be carried out by qualified
personnel only and with powered off device only.
4.2 Resetting to default settings
To reset user settings you can make use of a special restart procedure. Press RESET button
four times with 2 seconds intervals.
Push reset Push reset Push reset
Push reset
Factory default reset
Push reset
Normal reset
Figure 25 Router resetting to default procedure
Successful reset will be evidenced by fast and simultaneously flashing indictors ERROR and
STATUS.
By default, UHP-1000 router is provided with IP-address 192.168.222.222 with mask
255.255.255.248 (/29). Respectively, the computer should be provided with an address,
e.g. 192.168.222.217 with the same mask.
The default address is not shown in the route Table. And what is more, it disappears after
the first saving of the configuration. Thus the first thing to do, with the Telnet access, is to
set a new IP-address (it may be similar to the default address when required), exit the
session, and connect to the new address and only then save the configuration.
After the first saving of the configuration the ERROR and STATUS indicators stop flashing
simultaneously.