Owner Manual
12
A spark will appear which ignites the main burner on the minimum flame height. If the flame did not ignite repeat
this process 2-3 times. This will be required especially when you have replaced and installed a new LPG gas
cylinder.
When the flame is ignited keep holding the knob for around 5 seconds until the thermo-couple, which will keep
the main valve in an open position, warms up.
You may now release the knob. If however the flame is extinguished repeat the process once again until a stable
flame is achieved.
4.2 Regulation of the flame size
When the flame is burning the desired height of the flame may be adjusted and regulated by turning the knob
clockwise or counter-clockwise.
To achieve a higher flame turn the knob counter-clockwise to “Hi” position. To achieve a lower flame turn the knob
clockwise to “Lo” position (Fig 11).
Fig 11 – Adjusting the flame high
4.3 Device shutdown
To turn off the device, simultaneously press and turn the knob all the way clockwise (Fig 12). The gas supply will be
cut and the flame on burner will be turned off.
Fig 12 – Turning off the device
Additionally, close also the valve on the gas cylinder.
Hi
Lo
Off
WARNING
After 2-3 unsuccessful attempts terminate and check the connections. Try again in 10 minutes. If the installed gas
bottle is new or the fireplace has not been used for a longer period the first thing that needs to be done is to
release air from the gas linkage. In this case conducting a few attempts will be needed until the flame is ignited.