Quick guide UK Single Phase Equalizer Guide
Table of contents Product overview Product overview 2 Technical specifications 3 Before you start 3 Installation instructions 4 Troubleshooting 6 This kit consists of main components required to install an Easee Equalizer on a charging site with one or multiple circuits. All of the components are tested and guaranteed to work with the Easee Equalizer (E02-EQP). Not for use with the Easee Equalizer HAN version.
Technical specifications Before you start Eastron SDM120CT-RJ12 Measurements (mm): H:118 x W:18 x D:64 Voltage: 230V ac Network frequency: 50/60Hz (± 2%) IP-classification: IP51 Running temperature: -25°C - 55°C Primary connection: 2,5mm2 Current Input: RJ12 CT Clamp Output connection: RJ12 6P6C Mounting: DIN-rail Material: Self-extinguishing UI94 V-0 WARNING! This product shall only be installed, repaired or serviced by an suitable competent and qualified electrician.
1 Installing Equalizer Kit 4 WARNING! Turn off the power before you begin the installation. Use extreme caution and follow instructions carefully.
2 Setting up Equalizer Download the Easee Installer App via App store or Google play. To use the Easee Installer App, you must have an Easee Cloud account. If you already have an account, you can log in immediately. If you have created a site already, then please skip directly to step 2. 1. Create new Site: — — — — — — Fill in site information. Select Easee as the operator. Input Main fuse size Input Circuit fuse size and name. Input Wifi information, if available.
Troubleshooting Is the charger already installed? If the charger is already installed you will need to be invited as an administrator to access it in the Easee Installer App. — Do this by asking the site owner to invite you as an administrator via the Easee Cloud, or — Add the charger (master) to the users Easee app with the serial number and pin code. Then you will automatically become an administrator and will find the site under “update existing site” in the Easee Installer App.
LED colours meaning White, fast flashing – Booting White, breathing every 10s – Normal operation Red / white, switching – No WiFi added3 Red, flashing – No data from power meter4 Red, breathing every 10s – Error5 Purple, breathing every 10s – Offline operation6 Touch the Easee logo in the middle to check power consumption: Blue, fast flashing – High power consumption Blue, slow flashing – Low power consumption Count the flashes for percentage – 1 flash (10%), 2 flashes (20%), up to 10 flashes (100%) Amper
Assistance THIS DOCUMENT CONTAINS INFORMATION THAT IS SUBJECT TO CHANGE WITHOUT NOTICE. The latest version of this publication can be downloaded at http://easee.support Make sure to have the serial number available for the Easee Home and Equalizer to receive more rapid assistance. Easee Customer Excellence Telephone: 02039946725 Email: support@easee.