Installation Guidelines (continued)
HeaterWiring
Regardlessof the modelchosen, thereare5 wires insidethebase ofthe heater which
mustbe wiredcorrectly. Three wirecontactsarerequiredto obtain thepowersource.
Thewiringcodeisthesamefor120voltunits.
Theheatermust beprovideddisconnectdevice(switch/breaker)fromthesupplymains
having a contact separation in all poles that provide full disconnection with a contact
separationofatleast3mm.
OnthelargeinǦwallunittheblackishot,theredisneutral,andthegreenisground.On
the small inǦwall unit the black is hot, the blue is neutral and the green is ground. On
bothunitstheyellowandwhitewiresgodirectlytothethermostat.
Noexternalpowersupply isneeded.Anyattempttoattachanexternalpower supply
willcausedamagetotheinternalcomponentsandwillresultinproduct failure.
Whenconnectingmultipleunitstoasinglethermostat,theunitsmustbeconnectedin
parallel with all yellow and all white wire leads connected to their same respective
terminalsonthethermostat.
Failureto followtheseguidelines willresultin internaltransformerfailureandproduct
failure.
Thefiguresbelowdepictatypicalwiringprocedureusingconventional12/2wireonalargeheater.
ThermostatWiring
Use any conventional thermostat or doorbell wire to route the thermostat to the
heater.Unless the thermostat is diode protected or voltage sensitive to DC (positive
and negative), it doesn’t matter which heater thermostat wire goes to the respective
contactsonthebackofthermostat.
Consultthewiringinstructionsthatareincludedwiththethermostattomakesurethat
the low voltage thermostat being used is compatible with the 12 volt DC voltage
originating from the yellow and white thermostat wires from the heater.The
thermostatshouldbelocatedatleast5feetfromthelocationoftheinǦwallheater.
CZǦ1000FExistingConstructionInstallation
Theheatercutout
shouldhavea
minimalsizeof
16
1
/
2
(h)x12
3
/
4
(w).
Use the retrofit brackets as shown. Attach the heater unit to the wall, 6 ft.
(1.8m)orhigherabovethefloortothebottomoftheheaterunit.Thehigher
thebetter.Thehigher locationoftheheater insuresthatobstaclesin theroom
suchas furniture will not encumberthecirculationof the infrared heat waves
being generated from the heater. This assures even heat distribution and
preventscoldǦpocketsofair.
Page 10
Mounting Guidelines (CZ-1000F)
©2009 EarthWise Technologies, Inc
OPTIMAL
SITE
OPTIONAL
SITE
Usethefollowing
mountingbrackets
forheaterinstallation
inexistingconstruction.