Owner`s manual

Customer/Warranty Service: (800) 595-9605
Page 7
1.FIRST,inspectthepackageforanyobviousdamage.
2. Removetheprotectivepackagingmaterialsfromtheoutsideoftheheater
cabinetandfromthefrontfacepanel.
3. Removetheprotectivepackagingmaterialsfromtheinside
oftheheater’s
heat exchanger, making sure that all combustible materials have been
removedfromaroundtheblackceramicheatingelements.
4. Inspecttheunittomakesurethattherearenocrackintheblackceramic
heatingelements.
5. If noobvious damage is visible,proceed with theinstallation
instructions
asoutlineintheInstallationGuidelinesincludedwiththismanual.
Unpacking Your New CZ Infrared
Heater
Installation Guidelines
HowManyUnitsDoINeed?
Whendeterminingtherightnumberofunitstoinstallinaconventionalhome,
thefollowingitemsneedtobetakenintoconsideration:
 Theinsulationfactor,andwindowsize&placement
 Themeanoutsidetemperatureduringthecoldestdaysoftheyear
 Thesizeofeachroom
 The
overallsizeofthehome
 Thenumberoffloorsinvolved
 TheEntranceandEgresspoints
In lieu of overall engineering calculations and thermal loss calculations, a
generalrule ofthumbcanbe appliedtodeterminethe numberof unitstobe
installed:
Notes: Calculate 46 hours of running timeperday perheater installedto calculateBtu’s
andelectricalenergycost.Also,rememberthatmultipleunitinstallationsinlargerrooms
canbecoupledtothesamelowvoltagethermostatorregulatedseparately.
Page 16
©2009 EarthWise Technologies, Inc
Troubleshooting Your CZ Infrared
Problem Solution
Mostlikelyoneoftheceramicelementsis
burnt out or the connection to the
element is bad.Calla service technician
to determine the cause of the problem
and if necessary replace the defective
ceramicplate.
First, push the reset button. Next, check
thethermostatleads&listentodetermine
if the first fan is operating. If so, call a
servicetechnicianforinstallationofanew
heatrelay.
Mostlikelyyouhaveadefectivefanrelay.
Callaservicetechnicianforinstallation.
Heaterfanremainsrunningafter
20minutesofshutdown
First,pushtheresetbutton.Next,check
thethermostatleads.Shorttheleadsout
andiftheheaterturnsonyouhavea
defectivethermostat,otherwiseyouhave
adefectiverelayintheheater.
Callaservicetechnicianforinstallationof
anewrelay.
Heaterwon’tturnon
Checkforobstructionstothefanblades.
Ifthereare
none,youhaveadefectivefan
andmustfirstisolatethedefectivefan
unitforreplacement.
Callaservicetechnicianforinstallation.
Heaterisnoisy
Heaterdoesn’tappeartobe
gettinghotenough
Heaterdoesnotheatup