HYDRAULIC FILLING INSTRUCTIONS:
1. Open the air bleeder valve by turning counter clockwise
approximately four turns. Failure to open vent will cause “air
locking”, making lling of the hydraulic tank reservoir dicult.
SEE FIGURE 24.
2. Remove ller cap. SEE FIGURE 24.
3. Using a funnel in the ll spout pour 3 quarts of SAE10 hydraulic
oil. If hydraulic oil is dicult to obtain, automatic transmission
uid can be substituted. DO NOT mix hydraulic oil and
transmission uid.
4. Start Engine (see instructions in engine manual).
WARNING
PLEASE FOLLOW INSTRUCTIONS TO FILL YOUR TRAIL
WARRIOR LOG SPLITTER. FAILURE TO DO SO MAY
RESULT IN UNSATISFACTORY OPERATION. AN IM
PROPERLY FILLED HYDRAULIC SYSTEM MAY CREATE
CAVITATIONS OF THE HYDRAULIC CYLINDER AND
OVERALL POOR PERFORMANCE OR MAY CAUSE DAM
AGE TO YOUR TRAIL WARRIOR LOG SPLITTER.
Figure 24
air breather valve
ller cap