Datasheet
Application guidelines
Arrangement mounting flange for switching- and illumination element, PCB mounting
The arrangement of the mounting anges and their number is
determined by the size of the front panel or PCB. To ensure uni
-
form, tactile switching, we recommend a layout of the anges as
per adjacent sketch.
60 max.
60 max.
For large PCBs with several switching elements we recommend
the following procedure:
1. Fit the actuator to the front panel.
2. Clip the mounting ange to the rear of the intended actuator.
3. Screw the PCB with the components soldered to it to the
assembled mounting ange.
This arrangement applies to PCBs 1.6 mm thick.
Front plate
PCB
Spacer
Front plate
PCB
Spacer
Demontage Montageflansch
The tool Part No. 92-971.0 must be used for removing the moun-
ting ange from the actuator. Before removing the ange, the PCB
xing screws must be loosened.
If the number of actuators is insufcient, use the spacer Part. No.
92-965.0 which can be attached to the front panel.
The spacer can be adjusted to the following front panel thicknes-
ses: 1.5/2/2.2/3/3.5/4 mm and can be stuck to the back of the
panel free of dirt and grease.
Dismantling mounting flange
07/2019 § eao.com
971
92
01
02
03
04
09
14
17
18
19
22
31
41
45
51
56
57
61
70
71
82
84
92
96