Datasheet

Created:
Reviewed:
Approved:
Doc. No.
Version / status
Page
16/05/2017 / KRJ
16/05/2017 / KRJ
16/05/2017 / KRJ
19003064095
B / 2590 Series - released
2/3
EAO Systems AG
CH-4600 Olten
Telephone +41 62 286 91 11
Fax +41 62 296 21 62
www.eao.com
External dimensions:
See dimensional diagram 1
(Female M12 connector not included)
Note:
- The dimensional diagram shows the housing with the
emergency stop switch and M12 plug installed
- All side walls exhibit a pull of around 1°.
Dimensional diagram 1
Mounting
Mount mounting adapter onto mounting surface
Mount emergency stop Smart Box on one side (note direction
of mounting adapter on the housing)
Push the Smart Box onto the adaptor on the other side until it
audibly clicks into place
Alternatively, the module can be mounted on a standard top
hat rail, or it can be mounted on a base using screws on the
rear (see dimensional diagrams).
Dismantling
Pull out spring element using screwdriver
and lift Smart Box
Remove Smart Box from the other side
Alternative fixing
3x holes for
PT screw 2.5
(max. depth 6mm)