INSTALLATION & OWNER'S MANUAL THE EAGLE POWER II BATTERY BACK UP Control Box Battery Box PHONE (818) 764-6690 / TOLL FREE (800) 708-8848
PRE INSTALLATION INSTRUCTIONS ! CAUTION! BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY AND CAREFULLY FOLLOW ALL THE OPERATION INSTRUCTIONS. The Eagle-Power II Battery Back up is designed to provide back up power to a gate operator when the main AC supply voltage is interrupted or disconnected. There are two operations to the Eagle-Power II.
THE EAGLE POWER II INFORMATION & WARNINGS The following items are included with the POWER II: (A) Power II Control Box (B) 1 - 70 AH Battery Box (in a second box) (C) 1 - N/O Relay Output (D) 2 - 3/4" Raintight Flexible Conduits (E) 2 - 3/4" Raintight Conduit Connectors (F) 1 - 12VDC Output (Optional) (G) 1 - Instruction Manual Power II Approximate Dimensions: Control Box : 13 3/8" (h) x 18 5/8" (w) x 11" (d) Battery Box : 14 1/2" (h) x 12 1/2" (w) x 9" (d) (SEE PAGE #6 FOR FURTHER MEASUREMEN
INSTALLATION OF THE EAGLE POWER- II EAGLE POWER- II Eagle-2000-1HP Eagle-200-1HP Gate Size 10' 80** 160 15' 50** 100 20' 30** 60 70** 140 E-POWER II E-POWER II E-POWER II Eagle Operator Cycles Per 12 Hour Period Cycles Per 12 Hour Period With Extra Battery * * An extra 70AH battery comes with separate mounting box and cables - Weight: 65 lbs ** All ratings are for operators (including The Diamond Control Board) and three of the following accessories: Loop Detector, Receiver, MAG Lock, Ph
INSTALLATION OF THE EAGLE POWER- II CONNECTING THE AC LINE VOLTAGE: Electrically, the Power II is wired in series with the incoming AC supply from the breaker box to the operator. The connector labeled "AC In" is connected to the main AC supply. The "AC Out" is connected to the operator.
INSIDE OF THE EAGLE POWER II Control Box Battery Charger + 2000 Watt Inverter - Control Sub Panel AC OUT Hold Open AC IN Battery Terminals Battery Box - + 70 Ah Battery (5)
MOUNTING INSTALLATION THE EAGLE OF POWER THE E-I PS I 21" Mounting Bracket Holes 3/8" Diameter 13 3/8" 10" OC Rear View of Control Box 1" 18 1/2" 20" OC Drawings Not To Scale 16" 2 1/2" Mounting Bracket Holes 3/8" Diameter 12 1/2" 7 1/2" OC Rear View of Battery Box 2 1/2" 13 3/4" 14 1/2" OC (6)
THE EAGLE POWER II Recommended Installation with flex conduit Control Box Battery Box 3/4" Water-tight flexible conduit with fittings (7)
T E C HNIC AL S P E C IF IC AT IONS S P E C IF IC AT IONS & WAR R ANT Y INP UT V OLTAG E : B AT T E R Y: R E C HAR G E T IME : OUT P UT V OLTAG E : OUT P UT F R E QUE NC Y: OUT P UT C UR R E NT: S UR G E C UR R E NT: AC OUT P UT P OWE R : S UR G E P OWE R : R E LAY OUT P UT S : 105 - 125 VAC 12V DC / 70AH 8 HOUR S 115 VAC 60 Hz 15 AMP S 3 0 AMP S 2000 WAT T S 4000 WAT T S 10 AMP S ! C A UT ION! DO NOT E XC E E D T HE OUT P UT C APAC IT Y OF T HE P OWE R II.