Specification
Safety Data Sheet
Eagle Natural Seal Rev. 3/20/2015 Page 1 of 4
Eagle Natural Seal
Section 1 Product Description
Product Name: Eagle Natural Seal
Recommended Use: Penetrating concrete sealer
Supplier: Eagle I.F.P. Company, P.O. Box 100431, Nashville, TN 37224, 615-872-2710
Emergency Phone: INFOTRAC 1-800-535-5035
Section 2 Hazard identification
Category 3 Skin Irritation
Signal Word:
Warning.
Hazard Statement:
H316 Causes mild skin irritation
Precautionary Statement:
Prevention:
P261 Avoid breathing mist.
P280 Wear eye protection.
P270 Do not eat, drink, or smoke while using this product.
Response:
P301+P314 IF SWALLOWED: Get medical advice if you feel unwell.
P302+P353 IF ON SKIN: Rinse skin with water.
P304+P340+P342+P313 IF INHALED: Remove person to fresh air and keep comfortable for breathing. If
experiencing respiratory symptoms: Get medical advice.
P305+ P351+P338+P314 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses if present and easy to do - continue rinsing. Get medical advice if you feel unwell.
Section 3 Composition/ Information on Ingredients
CAS # OSHA PEL(TWA) ACGIH(TLV-TWA) Conc. (wt. %)
Triethoxyoctylsilane 2943-75-1 Not established Not established 6.0
Polyethylene oxide lauryl ether 9002-92-0 Not established Not established 0.30
Aminofunctional siloxane 68554-54-1 Not established Not established 2.0
Water 7732-18-5 N/A N/A 98.0
Section 4 First Aid Measures
Emergency First Aid Procedures
Skin: Immediately flush with water for 15 minutes. Seek medical attention if irritation persists.
Eyes: Flush with a gentle but large stream of clean water for 15 minutes, lifting the lower and upper eyelids
occasionally. Seek medical attention.
Inhalation: Move to fresh air and provide oxygen if breathing is difficult. Seek medical attention if irritation persists.
Ingestion: DO NOT INDUCE VOMITING. If vomiting occurs spontaneously, keep head below hips to prevent
aspiration of liquid into the lungs. Get medical attention immediately.
Section 5 Firefighting Procedures
Extinguishing Media: Dry chemical, CO2, alcohol-resistant foam
Flash Point (TCC): >212° F
Flammable Limits (% volume in air for solvents): LEL=N/A UEL=N/A
Special Fire Fighting Procedures: Firefighters wear NIOSH approved self-contained breathing apparatus. Cool
containers exposed to fire with water.
Section 6 Spill or Leak Procedures