Note that the multirotor will rearm instantly when the kill switch is disengaged, until about 3 seconds
after it’s engaged (in case the kill was accidental). Once 3 seconds have elapsed with the Kill Switch set,
the multirotor is permanently disarmed until you rearm it.
During RTH (including RTH test modes) the Gain Knob and Kill Switch inputs are disabled, to prevent
inadvertant changes in these inputs due to loss of reliable Rx signal.
Make sure that your radio does not trigger the kill switch during failsafe! If it does, the multirotor will