User Manual

USER GUIDE
125
Calibration error- see manual
This message is displayed if an error has occurred with the optional
altimeter calibration step.
Can't arm when RTH triggered!
If you try to arm when the MicroVector is in RTH mode (normally
because the mode/submode switches are set to “RTH Test”), this
message will appear.
Can't change when knob used!
The controller gains cannot be changed in the menus when the gain
knob is enabled for that gain.
Can't do that while flying!
You’ve attempted a menu operation that cannot be done while flying (or
armed).
If the altimeter or speed sensor(s) are drifting considerably, the
MicroVector may think that your fixed wing model is flying, when it
is not. Resetting home or rebooting the MicroVector should remedy
the issue.
Channel not detected!
This message will be displayed when you are running the Serial Rx
Learn wizard and the requested channel was not detected. This is ok if
the requested channel is not needed with your setup.
Compass Needs Recalibraton!
This indicates that the MicroVector has detected issues with the
compass calibration. Please recalibrate the compass. This can also
happen if the compass is rotated, not mounted firmly or level with the
MicroVector, or is temporarily near large metal objects.
Compass not Calibrated!
You have enabled the compass, but have not yet run the compass
calibration.
Too much pitch- keep it level
Too much roll- keep it level
If these messages appear during the horizontal rotation phase of
compass calibration, either you are pitching/rolling the model during
calibration, or you may need to rezero gyros and/or record flat level
mounting before calibration.
Cal error 1- retry/see manual
Cal error 2- retry/see manual
Cal error 3- retry/see manual
Cal error 4- retry/see manual
Cal error 5- retry/see manual
During compass calibration, these message may indicate one or more of
the following issues:
* There are sources of magnetic interference near the compass
(magnets, large metal objects, servos, etc.).
* There is a strong magnetic field anomaly near your location, such as
rocks or buildings with high magnetic fields. Try calibrating away from
such objects.
* A poor tumble or rotation technique is being used.
* You may need to rezero gyros and/or record flat level before
calibration.
* The MicroVector and GPS/MAG are not mounted with the same
orientation (level to each other), or the GPS/MAG is mounted loosely.
Control stick not centered!
Your control stick must be centered to arm the multirotor. If your
control stick is centered, please rerun the Receiver Analysis Wizard
again.
Elevator Issue: Rerun Wizard!
When you ran the Receiver Analysis Wizard, the MicroVector did not
detect correct movement of the elevator input. Check your wiring and
settings and run the wizard again.
Emergency reboot occurred!
If you see this message, DON’T FLY and contact support.
Error: External sensor issue!
This message indicates there was an issue communicating with either
the GPS/MAG, or the pitot speed sensor. If this happens repeatedly, a
cable is loose or damaged, or there’s a power or sensor problem.
Error: Internal sensor issue!
If you repeatedly see this message, DON’T FLY and contact support.