User Manual

USER GUIDE
124
14 Notification Messages
During boot-up and normal operation, the MicroVector constantly checks its status and settings, and the status
of any connected accessories. If an issue is detected, the MicroVector will display a message in the OSD
notification area either temporarily or until the issue is resolved, depending on the importance of the message.
The table below describes these messages, and what they mean. Note that it is unlikely you will ever see most
of these messages.
Onscreen Notification
Meaning of Message
2nd Aileron Input not Detectd
You configured the MicroVector to receive a mixed 2
nd
aileron signal
from your transmitter, but that signal is not detected. Check your
wiring and receiver settings.
2nd Ailrn Issue:Rerun Wizard!
You configured the MicroVector to receive a mixed 2
nd
aileron signal
from your transmitter, but that signal was not correctly detected when
you ran the Receiver Analysis Wizard. Please check correct operation of
the 2
nd
output from your transmitter, and rerun the wizard.
2nd Elevatr Input not Detectd
You configured the MicroVector to receive a mixed 2
nd
elevator signal
from your transmitter, but that signal is not detected. Check your
wiring and receiver settings.
2nd Elvtr Issue:Rerun Wizard!
You configured the MicroVector to receive a mixed 2
nd
elevator signal
from your transmitter, but that signal was not correctly detected when
you ran the Receiver Analysis Wizard. Please check correct operation of
the 2
nd
output from your transmitter, and rerun the wizard.
2nd Rudd Issue: Rerun
Wizard!
You configured the MicroVector to receive a mixed 2
nd
rudder signal
from your transmitter, but that signal was not correctly detected when
you ran the Receiver Analysis Wizard. Please check correct operation of
the 2
nd
output from your transmitter, and rerun the wizard.
2nd Rudder Input not Detected
You configured the MicroVector to receive a mixed 2
nd
rudder signal
from your transmitter, but that signal is not detected. Check your
wiring and receiver settings.
Aileron Issue: Rerun Wizard!
When you ran the Receiver Analysis Wizard, the MicroVector did not
detect correct movement of the aileron input. Check your wiring and
settings and run the wizard again.
Ailron or Elevatr undetected!
The MicroVector did not detect your aileron and/or elevator signal
during boot. Either these wires are not connected correctly, or your
receiver or transmitter was not powered during boot.
Airframe Not Set
You have not yet set the airframe type, which is required to use the
MicroVector’s flight controller.
Airframe Type Change Detected
This message will appear, along with an image of the presently selected
airframe type, when you first boot the MicroVector after changing the
airframe type. You must OK the airframe type by clicking the mode
switch once while this message is displayed on the screen.
Altimeter not detected!
If you repeatedly see this message, DON’T FLY and contact support.
Alt Hold Failing: Vib too hi!
The MicroVector has detected that there is too much vibration for
altitude hold to work correctly.
Alt Hold Reset: Vib too high!
The MicroVector has reset the altitude hold logic, due to continued
excessive vibration.
Alt Hold Failure: Vib too hi!
The altitude hold function has failed, due to continued excessive
vibration.