Specifications

RMIS Part No. 500549 Rev. B Page 3
Built-in self-test allows you to test various internal circuitries utilizing built-in test
capability.
Non-volatile memory to retain the pro
g
ram(s) and controller information durin
g
power
outages or seasonal shut downs. This information is maintained indefinitely.
A "real time" clock with non-volatile backup to maintain the actual date and time
during power outa
g
es without the need of batteries. This eliminates the need to
reprogram the clock every time there is a power outage.
Advanced circuitry to automatically monitor internal voltages and reset on-board
microprocessor circuitry during power “brown-out” or error conditions.
Automatic electronic fuse which resets intelli
g
ently based upon need. (No user fuses or
circuit breakers to reset or fail.)
Intelli
g
ent resumption of pro
g
ram execution after power outa
g
es to ensure that
program starts are not lost. The controller intelli
g
ently schedules irri
g
ation after any
outage while preserving the original water window.
Automatic detection of main line water breaks. Upon detection the controller shall:
shutdown all active irrigation, energize a Normally Open Master Valve (if selected),
condemn any future start times, and trigger audible and visual alarm indicators.
Automatic detection of unscheduled water flow. Upon detection the controller shall:
activate the Normally Open Master Valve (if selected), condemn any future start times,
and trigger audible and visual alarm indicators.
Automatic detection of upper stations flow limit. Upon detection the controller shall:
turn off the fault station, advance the pro
g
ram to the next station, condemn the
station from any future watering times, and trigger audible and visual alarm indicators.
2.0 FLOW CAPABILIITES
The controller shall have:
Programmable flow to enable or disable the flow sensor features.
Programmable flow sensor pipe sizes for standard Rain Master flow sensors (1.0, 1.25,
1.5, 2.0, 3.0, and 4.0 inch). Non-standard pipe sizes are also programmable.
Inputs for connectivity to a flow sensor. The controller shall read the frequency of the
sensor by sensing each time a contact closure appears at the input. The controller shall
source +8 VDC to the sensor.
Programmable main line flow limit from 1-999 GPM defines the maximum allowable flow
during scheduled irrigation.
Automatic detection of main line water breaks. Upon detection the controller shall:
shutdown all active irrigation, energize a normally open master valve (if selected),
condemn any future start times, and trigger audible and visual alarm indicators.
Programmable unscheduled flow limit from 0-999 GPM defines the maximum amount of
flow which will be tolerated during unscheduled irrigation periods.
Automatic detection of unscheduled water flow. Upon detection the controller shall:
energize the normally open master valve (if selected), condemn any future start times,
and trigger audible and visual alarm indicators.
Programmable station upper flow limits from 0-500 GPM.
Automatic detection of upper stations flow limit. Upon detection the controller shall: turn
off the fault station, advance the program to the next station, condemn the station from
any future watering times, and trigger audible and visual alarm indicators.