Specifications

Page 2 RMIS Part No. 500549 Rev. B
mode of operation.
Manual Rain Switch (Automatic Watering – No Waterin
) provides a means of quickly
turnin
g
off all irri
g
ation pro
g
rams without disturbin
g
the stored pro
g
ram(s). When the
switch is placed in the No Watering position the display shall show “RAIN OFF”
Connectivity for any one of the followin
g
: rain, moisture, or freeze sensor device. The
enablin
g
of this device can be performed on a per pro
g
ram basis. When the sensor is
active” irri
g
ation shall stop and the display will indicate that the sensor is active. This
feature allows non-irrigation programs to execute independent of this device.
T
he ability to select either ODD or EVEN day waterin
g
on a per pro
g
ram basis. (When
either of these features is selected, the controller shall not water on the 31st day of
the month.)
Selectable cycle and soak irri
g
ation pro
g
rammin
g
or conventional pro
g
rammin
g
on a
per-program basis.
Programmable cycle runtime, Max Cycle Time, and Soak Time on a per station basis.
Automatic minimization of the water window by intelligently scheduling station starts
when other stations are satisfying their SOAK TIMES.
Controller supports Quick Station pro
g
rammin
g
in the Cycle and Soak pro
g
rammin
g
mode.
T
he controller provides a display of the total runtime of the pro
g
ram usin
g
the
REVIEW feature of the controller. The cycle and soak feature intelli
g
ently displays the
total runtime of the pro
g
ram, the controller considers all soak delays, optimized
program features, water budget percentage and inter-station delays.
Optimized water savings. Re-calculated station run times are executed to the nearest
second.
1.3 Convenience Features
The controller shall have:
Easy to understand and use keyboard layout, provides ease of use durin
g
programming and review.
Multiple displays provide a simple way of programming and information review.
Durin
g
pro
g
ram execution the controller shall display the executin
g
pro
g
ram number,
the flow in GPM, and the station runtime countdown in hours, minutes and seconds.
Programmable Controller Security Access code to prevent unauthorized use or
modifications to be made of the controller’s pro
g
rams. This feature is enabled by
entering a security access code from 1 to 4 digits in length.
Review key to display all pro
g
ram parameters on a per pro
g
ram basis. Successive
invocation of the key shall display pro
g
ram parameters one by one. Depression and
subsequent hold of this key shall allow rapid review of program parameters.
1.4 Diagnostic and Fault Detection
The controller shall have:
Programmable audible alarm. When enabled this alarm will “chirp” once every six
seconds whenever any flow fault condition occurs. The alarm will continue until reset
by the user.
Automatic field wire fault detection enables the TWICE Two Wire Interface module to
sense a short or an open in the field wire and instantly turn off that station. The
TWICE display will report the fault condition any time a field wire fault occurs.