Specifications
RMIS Part No. 500549 Rev. B Page 1
EAGLE Two-Wire Irrigation Controller
Specifications
1.0 BASIC FEATURES
1.1 Standard Programming Capability
The controller shall have:
• Connectivity up to 36 independent stations and one master valve.
• Four (4) independently controllable irrigation pro
g
rams, with five (5) selectable start
times, for a total of 20 possible irrigation cycles per day.
• Runtime(s) for each station can be set from 1 minute to 9 hrs 59 minutes per station,
in one-minute increments.
• Quick Station(s) programming to allow rapid pro
g
rammin
g
of an entire block of
stations, with the same runtime.
• Water Days for each program can be based on a seven-day cycle or a skip-by-day
cycle, which allows a pro
g
ram to skip from 1 to 30 days between waterin
g
cycles.
The water days can be restricted with the selection of ODD/EVEN calendar days.
• Manually activated system check/syrin
g
e cycle to sequentially run each station for a
user selectable time, with a range from one minute up to nine minutes.
• Manually activated program cycle to execute a pro
g
ram independently of its
programmed start time and water days.
• Manually activated station cycle to operate a sin
g
le station for a selectable period of
time from 1 minute to 9 hours 59 minutes.
• Programmable Master Valve to utilize and control a Master Valve on a per pro
g
ram
basis.
• Confi
g
urable Master Valve Type to select either a Normally Open Master Valve or a
Normally Closed Master Valve.
• Programmable Pump independent of the Master Valve on a per program basis.
• Programmable stacking or non-stackin
g
operation of the pro
g
rams. In the event that
pro
g
rammed start times either within a pro
g
ram or between pro
g
rams should overlap,
or coincide, the controller can either be pro
g
rammed to sequentially execute one
program after the other program has completed (Stack Mode) or to simultaneously
execute all programs as their programmed start times occur (No Stack Mode).
• Programmable delay time between station executions. The pro
g
rammed delay time
can be between 0 to 255 seconds (4 minutes 15 seconds). This capability allows slow-
closing valves to completely shut off, before the next valve turns on.
1.2 Water Conservation Features
The controller shall have:
• Flow sensing and control (refer to section 2.0)
• Evapotranspiration (ET) based scheduling (refer to section 3.0)
• Percenta
g
e ad
j
ustment on a per pro
g
ram basis to allow an increase or decrease of all
station runtimes within that pro
g
ram. The percenta
g
e shall allow ad
j
ustment from 0 to
300% in 1% increments.
• Programmable rain shut off in order to delay the start of irri
g
ation after a rain storm.
T
he controller shall not water durin
g
the pro
g
rammed delay period (from one to seven
days). After the delay period has expired the controller shall return to the automatic