Installation Instructions
Table Of Contents
(Figure 4.3)
FIXED TERMINAL INSTALLATION HANDBOOK
E
N
G
L
I
S
H
30/42 09/2001
IH – PS8433EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
4.3.3 Wall unit
• Select the location for the wall unit:
the wall unit must be located in a sheltered room,
the ambient temperature for normal operation, must be between
+10°C and +35°C,
the wall unit must be installed at least 25 cm. from the floor,
the wall unit must be connected to the 110 V/230 V –50 Hz or
60 Hz mains supply (nominal conditions).
• Position the drilling template supplied with the wall unit.
• Drill 4 holes at the locations marked A and B .
• Attach the bracket at the location marked A .
Note: The type of attachment to be used must be appropriate to the type
of partition supporting the wall unit (weight of unit including the
BER: 8.5 kg).
• Unscrew the four captive screws of the wall unit cover, then remove
the wall unit cover.
• Position the wall unit on the bracket, and then attach by means of two
screws at the locations marked B .