Installation Instructions

(Figure 4.3)
FIXED TERMINAL INSTALLATION HANDBOOK
E
N
G
L
I
S
H
30/42 09/2001
IH – PS8433EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
4.3.3 Wall unit
Select the location for the wall unit:
the wall unit must be located in a sheltered room,
the ambient temperature for normal operation, must be between
+10°C and +35°C,
the wall unit must be installed at least 25 cm. from the floor,
the wall unit must be connected to the 110 V/230 V –50 Hz or
60 Hz mains supply (nominal conditions).
Position the drilling template supplied with the wall unit.
Drill 4 holes at the locations marked A and B .
Attach the bracket at the location marked A .
Note: The type of attachment to be used must be appropriate to the type
of partition supporting the wall unit (weight of unit including the
BER: 8.5 kg).
Unscrew the four captive screws of the wall unit cover, then remove
the wall unit cover.
Position the wall unit on the bracket, and then attach by means of two
screws at the locations marked B .