4.3.2 MSW/SSW – wall unit link cable (line–connected
terminal)
Note: If a modem is used, use cable SPE17 supplied with the modem
(see Section 1.3, Document <3>).
• Route the cable near to the location of wall unit following the safety
precautions given in Chapter 3.
• On the cable ends, connect the STOCKO 8–pin female F connector
included in the connection kit and the Sub–D 9–pin male connector
(local supply). Follow the connection layout given in Table 4.1.
Note: The length of the cable must not exceed 300 meters.
• Connect the cable to the connector on the radio switch (see
Section 1.3, Document <4>) or to the modem (see Section 1.3,
Document <3>).
LINE CONNECTED FIXED TERMINAL SIDE
STOCKO 8–PIN FEMALE CONNECTOR
RADIO SWITCH SIDE Sub–D
9–PIN MALE CONNECTOR
NAME OF
SIGNAL
I/O DESIGNATION PIN NUMBER PIN NUMBER
NAME OF
SIGNAL
CO–EDP O Data (Positive)
11
1
p
air
TXF
CO–EDM O Data (Negative)
2
1
pa
i
r
6
NTXF
CO–RDP I Data (Positive) 32
1
p
air
RXF
CO–RDM I Data (Negative)
1
pa
i
r
47
NRXF
CO–HRP I Clock (Positive)
54
1i
HRF
CO–HRM I Clock
(Negative)
1 pair
69
NHRF
Masse Earth
73
1
p
air
Masse
Blindage Shielding
1
pa
i
r
88
Blindage
Table 4.1 LINE CONNECTED TERMINAL / MSW/SSW CONNECTION