Installation Instructions

MOBILE TERMINAL INSTALLATION HANDBOOK (BER VERSION B)
E
N
G
L
I
S
H
30/32 09/2001
IH – PS8432EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
Note: Two extraction keys (item 1) are supplied with the CCP. These
are used to remove the CCP from its holder. To do this:
place a key (item 1) on each side of the CCP (item 4) turning
the pins inwards,
insert the two keys (item 1) in the lateral openings of the
desktop holder,
press the keys (item 1) to unclip the CCP on each side,
remove the keys (item 1) and the CCP (item 4).
Install the speaker microphone holder (item 7) and secure it with the
two screws (item 8).
Install the speaker microphone (item 2) on its holder (item 7).
4.4 CHECKING THE TERMINAL INSTALLATION
Connect the power supply cable to the battery observing the polarity
indicated in Section 4.3.3.
Having completed the installation, various checks should be carried out
before starting up the terminal.
Check the:
presence and polarity of the power supply voltage,
electrical continuity between the body of the antenna coaxial plug and
ground,
installation resistance between the antenna strand and chassis
ground,
continuity between the antenna and the core of the coaxial plug
external connections to the terminal.
The voltage drop in the power supply cable should be less than 300 mV,
for a current of 3 A (with a 10 W terminal transmission power).