Installation Instructions
Table Of Contents
(Plate A–IX)
MOBILE TERMINAL INSTALLATION HANDBOOK (BER VERSION B)
E
N
G
L
I
S
H
28/32 09/2001
IH – PS8432EAE01
This document is the property of MATRA NORTEL COMMUNICATIONS and should not be copied or circulated without permission
4.3.8 CCP
4.3.8.1 CCP car DIN holder
Note: The CCP car DIN holder (item 2) has two removable metal
stops (item 5). As these stops are asymmetrical, the distance
between them depends on how they are mounted. The
distance can be either 80 mm, 85 mm or 91 mm.
Before installing the car DIN holder, make sure the distance is
91 mm. If it is not, change the way they are mounted so that the
damping pad (item 6) is turned towards the CCP.
• Remove the two adhesive tapes retaining the two fasteners (item 3)
on the CCP car DIN holder (item 2).
• Position the car DIN holder (item 2) in the opening of the mounting
surface (item 1).
• Install the two fasteners (item 3) securing the CCP car DIN
holder (item 2),
and/or
fit the four slots (item 7) and four fasteners (see item 3, plate A–II
and A–III) of the desktop mounting kit,
• Unscrew the screw (item 4) of each fastener (item 3) until the CCP car
DIN holder (item 2) is secured.
• Extract the system cable connector through the opening of the CCP
car DIN holder.